Evidence map›Paper›PMID 27529175›Full record

ArticlePloS one2016

Test-Retest Reliability of 10 Hz Conditioning Electrical Stimulation Inducing Long-Term Potentiation (LTP)-Like Pain Amplification in Humans.

Weiwei Xia, Carsten Dahl Mørch, Ole Kæseler Andersen

Registry-linked trialOpen access · goldAbstract read
In one paragraph

Article in PloS one, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03362827 (Assessment of Long-term Potentiation), which is not on this map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.3field-weighted citation impact, top 39% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT03362827 unknown statusnot on this mapstarted 2018, after this paper: background citation

Assessment of Long-term Potentiation (LTP)-Like Pain Amplification in Chronic Low Back Pain Patients

TypeobservationalSponsorPeking University People's HospitalRan2018 to 2018Enrolled50ConditionsLow Back PainArmsChronic low back pain patients, Subjects without chronic low back pain
3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 2 countries.

Weiwei XiaCenter for Neuroplasticity and Pain (CNAP), SMI ®, Department of Health Science and Technology, Aalborg University, Aalborg, Denmark.
Carsten Dahl MørchCenter for Neuroplasticity and Pain (CNAP), SMI ®, Department of Health Science and Technology, Aalborg University, Aalborg, Denmark.
Ole Kæseler AndersenCenter for Neuroplasticity and Pain (CNAP), SMI ®, Department of Health Science and Technology, Aalborg University, Aalborg, Denmark.
Aalborg University · DKJilin University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background10 Hz conditioning electrical stimulation (CES) has been shown to induce long-term potentiation (LTP)-like pain amplification similar to traditional 100 Hz CES in healthy humans. The aim of this study was to assess the test-retest reliability and to estimate sample sizes required for future crossover and parallel study designs.

methodsThe 10 Hz paradigm (500 rectangular pulses lasting 50 s) was repeated on two separate days with one week interval in twenty volunteers. Perceptual intensities to single electrical stimulation (SES) at the conditioned skin site and to mechanical stimuli (pinprick and light stroking) in immediate vicinity to the conditioned skin site were recorded. Superficial blood flow (SBF) was assessed as indicator of neurogenic inflammation. All outcome measures were assessed with 10 min interval three times before and six times after the CES. The coefficient of variation and intra-class correlation coefficient were calculated within session and between sessions. Sample sizes were estimated for future crossover (Ncr) and parallel (Np) drug testing studies expected to detect a 30% decrease for the individual outcome measure following 10 Hz CES.

resultsPerceptual intensity ratings to light stroking (Ncr = 2, Np = 33) and pinprick stimulation (491 mN) (Ncr = 6, Np = 54) increased after CES and showed better reliability in crossover than parallel design. The SBF increased after CES, and then declined until reaching a plateau 20 minutes postCES. SBF showed acceptable reliability both in crossover and parallel designs (Ncr = 3, Np = 13). Pain ratings to SES were reliable, but with large estimated sample sizes (Ncr = 634, Np = 11310) due to the minor pain amplification.

conclusionsThe reliability of 10 Hz CES was acceptable in inducing LTP-like effects in the assessments of superficial blood flow, heterotopic mechanical hyperalgesia, and dysesthesia in terms of sample sizes for future crossover study designs.

Indexed as

Electric StimulationLong-Term PotentiationAdultFemaleHot TemperatureHumansMalePainPain ThresholdPerceptionReproducibility of ResultsSensationYoung Adult

Identifiers

PMID27529175
PMCPMC4986952
OpenAlexW2507804136

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.