Evidence map›Paper›PMID 27526710›Full record

ArticleBMC ophthalmology2016

Refractive shift of silicone oil tamponade in pseudophakic eye.

Wei Fang, Jiuke Li, Xiaohong Jin, Jing Zhai, Yuanmin Dai, Yumin Li

Open access · goldAbstract read
In one paragraph

Article in BMC ophthalmology, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.6field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Wei FangOphthalmology Department of SIR RUN RUN SHAW hospital, SIR RUN RUN SHAW Institute of Clinical Medicine of Zhejiang University, #3 Qingchun East Road, Hangzhou, Zhejiang, 310016, People's Republic of China.
Jiuke LiOphthalmology Department of SIR RUN RUN SHAW hospital, SIR RUN RUN SHAW Institute of Clinical Medicine of Zhejiang University, #3 Qingchun East Road, Hangzhou, Zhejiang, 310016, People's Republic of China.
Xiaohong JinOphthalmology Department of SIR RUN RUN SHAW hospital, SIR RUN RUN SHAW Institute of Clinical Medicine of Zhejiang University, #3 Qingchun East Road, Hangzhou, Zhejiang, 310016, People's Republic of China.
Jing ZhaiOphthalmology Department of SIR RUN RUN SHAW hospital, SIR RUN RUN SHAW Institute of Clinical Medicine of Zhejiang University, #3 Qingchun East Road, Hangzhou, Zhejiang, 310016, People's Republic of China.
Yuanmin DaiOphthalmology Department of SIR RUN RUN SHAW hospital, SIR RUN RUN SHAW Institute of Clinical Medicine of Zhejiang University, #3 Qingchun East Road, Hangzhou, Zhejiang, 310016, People's Republic of China.
Yumin LiOphthalmology Department of SIR RUN RUN SHAW hospital, SIR RUN RUN SHAW Institute of Clinical Medicine of Zhejiang University, #3 Qingchun East Road, Hangzhou, Zhejiang, 310016, People's Republic of China. liyumin77@hotmail.com.
Zhejiang University · CNSir Run Run Shaw Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundRefraction change of silicone oil (SO) tamponade in phakic and aphakic eye has been studied thoroughly; however, it is rarely studied in pseudophakic eye. In this paper we aimed to deduce a theoretical formula predicting refractive shift of silicone oil tamponade in pseudophakic eye and compared it with clinical findings.

methodA theoretical formula was deduced through strict geometric optical principles under the Helmholtz Schematic eye model. Pre/postoperative refractive status of patients who previously underwent phacoemulsification, intraocular lens (IOL) implant, vitrectomy, SO tamponade and required SO extraction was studied.

resultsTwenty-six patients (27 eyes, 13 males and 13 females) were studied. Refractive error of SO-off was -1.88 ± 2.73D, and of SO-in was 2.02 ± 3.90. Refractive shift of SO tamponade was -3.90 ± 1.74D. Refractive shift was significantly associated with refractive power of IOL (r = -0.7903, p < 0.0001, Pearson correlation test) and anterior chamber distance (ACD, r = 0.3840, p = 0.0480, Pearson correlation test). Theoretical refractive shift was -4.10 ± 1.51D, and there was no significant difference between the theoretical and the clinical refractive shift (p = 0.3329, Paired T test).

conclusionsRefractive shift of SO tamponade in pseudophakic eye correlates with refractive power of implanted IOL and ACD, and strong correlation between theoretical formula and clinical findings was detected.

Indexed as

EndotamponadeLenses, IntraocularLens Implantation, IntraocularSilicone OilsFemaleHumansMaleModels, TheoreticalPhacoemulsificationPseudophakiaRefraction, OcularRefractive ErrorsVisual AcuityVitrectomySilicone OilsArtificial lensRefractive shiftSilicone oil tamponadeTheoretical formula

Identifiers

PMID27526710
PMCPMC4986366
OpenAlexW2508650463

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.