Evidence map›Paper›PMID 27513687›Full record

SynthesisPediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies2016

Poor Adherence to Lung-Protective Mechanical Ventilation in Pediatric Acute Respiratory Distress Syndrome.

Shan L Ward, Carson M Quinn, Stacey L Valentine, Anil Sapru, Martha A Q Curley, Douglas F Willson, Kathleen D Liu, Michael A Matthay, Heidi R Flori

Registry-linked trialAbstract readMeta-Analysis
In one paragraph

Synthesis in Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03768921 (Use of Electrical Impedance Tomography in Children With Syndrome of Acute Respiratory Disorder), which is not on this map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT03768921 nacompletednot on this mapstarted 2018, after this paper: background citation

Use of Electrical Impedance Tomography in Children With Syndrome of Acute Respiratory Disorder

TypeinterventionalSponsorUniversidade Metodista de PiracicabaRan2018 to 2019Enrolled20ConditionsRespiratory Distress SyndromeArmsPEEP Titriation
3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Article
  2. Observational
  3. Article
  4. Article
  5. Ventilator-induced lung injury in children: a reality?Annals of translational medicine · 2019
    Review
  6. Review
  7. Association Between Tidal Volumes Adjusted for Ideal Body Weight and Outcomes in Pediatric Acute Respiratory Distress Syndrome.Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies · 2019
    Article
  8. Potential Acceptability of a Pediatric Ventilator Management Computer Protocol.Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies · 2017
    Article
  9. Variability in Usual Care Mechanical Ventilation for Pediatric Acute Respiratory Distress Syndrome: Time for a Decision Support Protocol?Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies · 2017
    Observational
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

9 authors.

Shan L Ward1Division of Critical Care, Department of Pediatrics, UCSF Benioff Children's Hospital San Francisco, San Francisco, CA.2Department Volunteer Services, UCSF Benioff Children's Hospital Oakland, Oakland, CA.3Department of Pediatric Critical Care, UMass Memorial Medical Center, Worcester, MA.4Division of Critical Care Medicine, Department of Pediatrics, Mattel Children's Hospital at UCLA Medical Center, Los Angeles, CA.5Department of Family and Community Health, University of Pennsylvania, School of Nursing, Philadelphia, PA.6Division of Pediatric Critical Care, Children's Hospital of Richmond at VCU, Richmond, VA.7Department of Medicine, UCSF Medical Center, San Francisco, CA.8Department of Anesthesia, UCSF Medical Center, San Francisco, CA.9Cardiovascular Research Institute, UCSF Medical Center, San Francisco, CA.10Division of Pediatric Critical Care Medicine, C.S. Mott Children's Hospital, Ann Arbor, MI.
Carson M Quinn
Stacey L Valentine
Anil Sapru
Martha A Q Curley
Douglas F Willson
Kathleen D Liu
Michael A Matthay
Heidi R Flori

Funding

Resolution of Clinical Lung InjuryR37HL051856 · NHLBI · UNIVERSITY OF CALIFORNIA, SAN FRANCISCO · PI MATTHAY, MICHAEL A. · 2006 to 2015
$3.9M
Research Training in Pediatric Critical Care MedicineT32HD049303 · NICHD · UNIVERSITY OF CALIFORNIA, SAN FRANCISCO · PI JEFFREY R FINEMAN · 2006 to 2026
$3.1M
RESOLUTION OF CLINICAL LUNG INJURYR01HL051856 · NHLBI · UNIVERSITY OF CALIFORNIA SAN FRANCISCO · PI MATTHAY, MICHAEL A. · 1996 to 2005
$1.7M
NHLBI NIH HHS R01 HL051856NHLBI NIH HHS R37 HL051856NICHD NIH HHS T32 HD049303
6 · The paper itself

Abstract

objectivesTo determine the frequency of low-tidal volume ventilation in pediatric acute respiratory distress syndrome and assess if any demographic or clinical factors improve low-tidal volume ventilation adherence.

designDescriptive post hoc analysis of four multicenter pediatric acute respiratory distress syndrome studies.

settingTwenty-six academic PICU. PATIENTS: Three hundred fifteen pediatric acute respiratory distress syndrome patients. MEASUREMENTS AND MAIN

resultsAll patients who received conventional mechanical ventilation at hours 0 and 24 of pediatric acute respiratory distress syndrome who had data to calculate ideal body weight were included. Two cutoff points for low-tidal volume ventilation were assessed: less than or equal to 6.5 mL/kg of ideal body weight and less than or equal to 8 mL/kg of ideal body weight. Of 555 patients, we excluded 240 for other respiratory support modes or missing data. The remaining 315 patients had a median PaO2-to-FIO2 ratio of 140 (interquartile range, 90-201), and there were no differences in demographics between those who did and did not receive low-tidal volume ventilation. With tidal volume cutoff of less than or equal to 6.5 mL/kg of ideal body weight, the adherence rate was 32% at hour 0 and 33% at hour 24. A low-tidal volume ventilation cutoff of tidal volume less than or equal to 8 mL/kg of ideal body weight resulted in an adherence rate of 58% at hour 0 and 60% at hour 24. Low-tidal volume ventilation use was no different by severity of pediatric acute respiratory distress syndrome nor did adherence improve over time. At hour 0, overweight children were less likely to receive low-tidal volume ventilation less than or equal to 6.5 mL/kg ideal body weight (11% overweight vs 38% nonoverweight; p = 0.02); no difference was noted by hour 24. Furthermore, in the overweight group, using admission weight instead of ideal body weight resulted in misclassification of up to 14% of patients as receiving low-tidal volume ventilation when they actually were not.

conclusionsLow-tidal volume ventilation is underused in the first 24 hours of pediatric acute respiratory distress syndrome. Age, Pediatric Risk of Mortality-III, and pediatric acute respiratory distress syndrome severity were not associated with improved low-tidal volume ventilation adherence nor did adherence improve over time. Overweight children were less likely to receive low-tidal volume ventilation strategies in the first day of illness.

Indexed as

AdolescentChildChild, PreschoolCritical CareFemaleGuideline AdherenceHumansInfantInfant, NewbornIntensive Care Units, PediatricMalePractice Guidelines as TopicPractice Patterns, Physicians'Respiration, ArtificialRespiratory Distress Syndrome

Identifiers

PMID27513687
PMCPMC5199719

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.