Evidence map›Paper›PMID 27513664›Full record

ArticlePloS one2016

Predicting Trabecular Bone Stiffness from Clinical Cone-Beam CT and HR-pQCT Data; an In Vitro Study Using Finite Element Analysis.

Eva Klintström, Benjamin Klintström, Rodrigo Moreno, Torkel B Brismar, Dieter H Pahr, Örjan Smedby

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
2.5field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 29 citations in OpenAlex.

  1. High-impact exercise stimulated localised adaptation of microarchitecture across distal tibia in postmenopausal women.Osteoporosis international : a journal established as result of cooperation between the European Foundation for Osteoporosis and the National Osteoporosis Foundation of the USA · 2021
    Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 2 countries.

Eva KlintströmDepartment of Medical and Health Science, Division of Radiology, Linköping University, Linköping, Sweden.ORCID http://orcid.org/0000-0003-0884-899X
Benjamin KlintströmCenter for medical Image Science and Visualization, Linköping University, Linköping, Sweden.
Rodrigo MorenoKTH Royal Institute of Technology, School of Technology and Health, Huddinge, Stockholm, Sweden.
Torkel B BrismarDepartment of Clinical Science, Intervention and Technology at Karolinska Institutet, Stockholm, Sweden.
Dieter H PahrInstitute of Lightweight Design and Structural Biomechanics, TU Wien, Vienna, Austria.
Örjan SmedbyDepartment of Medical and Health Science, Division of Radiology, Linköping University, Linköping, Sweden.
Linköping University · SEKarolinska University Hospital · SEKTH Royal Institute of Technology · SETU Wien · AT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Stiffness and shear moduli of human trabecular bone may be analyzed in vivo by finite element (FE) analysis from image data obtained by clinical imaging equipment such as high resolution peripheral quantitative computed tomography (HR-pQCT). In clinical practice today, this is done in the peripheral skeleton like the wrist and heel. In this cadaveric bone study, fourteen bone specimens from the wrist were imaged by two dental cone beam computed tomography (CBCT) devices and one HR-pQCT device as well as by dual energy X-ray absorptiometry (DXA). Histomorphometric measurements from micro-CT data were used as gold standard. The image processing was done with an in-house developed code based on the automated region growing (ARG) algorithm. Evaluation of how well stiffness (Young's modulus E3) and minimum shear modulus from the 12, 13, or 23 could be predicted from the CBCT and HR-pQCT imaging data was studied and compared to FE analysis from the micro-CT imaging data. Strong correlations were found between the clinical machines and micro-CT regarding trabecular bone structure parameters, such as bone volume over total volume, trabecular thickness, trabecular number and trabecular nodes (varying from 0.79 to 0.96). The two CBCT devices as well as the HR-pQCT showed the ability to predict stiffness and shear, with adjusted R2-values between 0.78 and 0.92, based on data derived through our in-house developed code based on the ARG algorithm. These findings indicate that clinically used CBCT may be a feasible method for clinical studies of bone structure and mechanical properties in future osteoporosis research.

Indexed as

Finite Element AnalysisAbsorptiometry, PhotonAlgorithmsBone DensityCancellous BoneCone-Beam Computed TomographyHumansIn Vitro TechniquesOsteoporosisRadiographic Image Interpretation, Computer-AssistedTomography, X-Ray Computed

Identifiers

PMID27513664
PMCPMC4981445
OpenAlexW2510862730

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.