Transfer characteristics of subretinal visual implants: corneally recorded implant responses.

K Stingl, K U Bartz-Schmidt, A Braun, F Gekeler, U Greppmaier, A Schatz, A Stett, T Strasser, V Kitiratschky, E Zrenner

Open access · hybridAbstract readClinical Trial
In one paragraph

Trial report in Documenta ophthalmologica. Advances in ophthalmology, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.0field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. An update on retinal prostheses.Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology · 2020
    Review
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 1 country.

K StinglCentre for Ophthalmology, University of Tübingen, Schleichstr. 12-16, 72076, Tübingen, Germany.
K U Bartz-SchmidtCentre for Ophthalmology, University of Tübingen, Schleichstr. 12-16, 72076, Tübingen, Germany.
A BraunRetina Implant AG, Gerhard-Kindler-Straße 8, 72770, Reutlingen, Germany.
F GekelerCentre for Ophthalmology, University of Tübingen, Schleichstr. 12-16, 72076, Tübingen, Germany.
U GreppmaierRetina Implant AG, Gerhard-Kindler-Straße 8, 72770, Reutlingen, Germany.
A SchatzCentre for Ophthalmology, University of Tübingen, Schleichstr. 12-16, 72076, Tübingen, Germany.
A StettNMI Natural and Medical Sciences Institute at the University of Tübingen, Markwiesenstr. 55, 72770, Reutlingen, Germany.
T StrasserCentre for Ophthalmology, University of Tübingen, Schleichstr. 12-16, 72076, Tübingen, Germany.
V KitiratschkyCentre for Ophthalmology, University of Tübingen, Schleichstr. 12-16, 72076, Tübingen, Germany. veronique.kitiratschky@gmail.com.
E ZrennerCentre for Ophthalmology, University of Tübingen, Schleichstr. 12-16, 72076, Tübingen, Germany.
University of Tübingen · DENatural and Medical Sciences Institute · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe subretinal Alpha IMS visual implant is a CE-approved medical device for restoration of visual functions in blind patients with end-stage outer retina degeneration. We present a method to test the function of the implant objectively in vivo using standard electroretinographic equipment and to assess the devices' parameter range for an optimal perception.

methodsSubretinal implant Alpha IMS (Retina Implant AG, Reutlingen, Germany) consists of 1500 photodiode-amplifier-electrode units and is implanted surgically into the subretinal space in blind retinitis pigmentosa patients. The voltages that regulate the amplifiers' sensitivity (V

resultsCRIRs are a meaningful tool for assessing the transfer characteristic curves of the electronic implant in vivo monitoring the implants' voltage output as a function of log luminance in a sigmoidal shape. Changing the amplifiers' sensitivity (V

conclusionsThe technical function of subretinal visual implants can be measured objectively using a standard electroretinographic setup. CRIRs help the patient to optimise the perception by adjusting the gain and luminance range of the device and are a useful tool for clinicians to objectively assess the function of subretinal visual implants in vivo.

Indexed as

Electrodes, ImplantedAdultBlindnessCorneaElectroretinographyHumansPhotic StimulationRetinaRetinal DegenerationVision, OcularArtificial visionElectrophysiologyHereditary retinal diseasesNeuroprostheticsRetinitis pigmentosaSubretinal visual implant

Identifiers

PMID27510912
PMCPMC5052310
OpenAlexW2503071964

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.