ArticleJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology2017
The radiation dose to overweighted patients undergoing myocardial perfusion SPECT can be significantly reduced: validation of a linear weight-adjusted activity administration protocol.
Article in Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 8 citations in OpenAlex.
- Quality metrics for single-photon emission computed tomography myocardial perfusion imaging: an ASNC information statement.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2023Review
- Retrospective fractional dose reduction in Tc-99m cardiac perfusion SPECT/CT patients: A human and model observer study.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2021Article
- Patient-specific SPECT imaging protocols to standardize image noise.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2021Article
- Improving Diagnostic Accuracy in Low-Dose SPECT Myocardial Perfusion Imaging With Convolutional Denoising Networks.IEEE transactions on medical imaging · 2020Article
- Personalized Models for Injected Activity Levels in SPECT Myocardial Perfusion Imaging.IEEE transactions on medical imaging · 2019Article
- Myocardial perfusion scintigraphy dosimetry: optimal use of SPECT and SPECT/CT technologies in stress-first imaging protocol.Clinical and translational imaging · 2016Review
Corrections and comments
- Commented on by
Authors and funding
7 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundLarge body size can cause a higher proportion of emitted photons being attenuated within the patient. Therefore, clinical myocardial perfusion SPECT (MPS) protocols often include unproportionally higher radioisotope activity to obese patients. The aim was to evaluate if a linear weight-adjusted low-dose protocol can be applied to obese patients and thereby decrease radiation exposure. METHODS AND
resultTwo hundred patients (>110 kg, BMI 18-41, [n = 69], ≤ 110 kg, BMI 31-58, [n = 131]) underwent
conclusionLinear low-dose weight-adjusted protocol of 2.5 MBq/kg in MPS can be applied over a large weight span without loss of counts or image quality, resulting in a significant reduction in radiation exposure to obese patients.