ArticleBiomedical engineering online2016
Correcting motion in multiplanar cardiac magnetic resonance images.
Article in Biomedical engineering online, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 5 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 3 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundMisalignment in cardiac magnetic resonance (CMR) images can adversely affect three-dimensional left ventricle modelling and downstream quantitative analysis. Currently, there are two types of approaches for dealing with realignment and motion distortion problems, one image based and the other geometry based. Image-based approaches are limited by the inherent non-homogeneity and anisotropy of CMR images. Geometry-based approaches rely on idealized models and over-simplified assumptions. This study was motivated by the need for a robust and effective approach for correcting motion related distortions due to misalignment in CMR images.
methodsA cine cardiac magnetic resonance image sequence was acquired using our routine clinical imaging protocol. The left ventricular endocardium was delineated manually with software assistance on all long and short-axis images. Long and short-axis contours were projected onto a patient-based coordinate system and then realigned using iterative registration. The realigned contour points were used to reconstruct the shape of the left ventricle for quantitative validation.
resultsThe method was tested on five myocardial infarction patients whose images showed substantial misalignment. Realignment time was about 16 seconds per case, using a 2.5 GHz CPU desktop with obvious elimination of the distortion in the reconstructed model. Using the long-axis contour as a reference in evaluating the reconstructed models, it was apparent that the models with realigned contours had better accuracy than the non-realigned ones.
conclusionThis study presents a novel, geometry-based method for correcting motion distortions in CMR images. The method incorporates (1) manual delineation, (2) registration based on a generalized, iterative closest point algorithm, and (3) reconstruction of the shape of the left ventricle for quantitative validation. The effectiveness of our approach is corroborated both visually and by quantitative assessment. We envision the use of our method in current clinical practice as a means of improving accuracy in the evaluation of cardiac function.
Indexed as