ArticleSkeletal radiology2016
Advanced metal artifact reduction MRI of metal-on-metal hip resurfacing arthroplasty implants: compressed sensing acceleration enables the time-neutral use of SEMAC.
Article in Skeletal radiology, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
19 citing papers in PubMed.
- Accuracy of CBCT and dental-MRI for detecting peri-implant bone defects at single titanium implants: an in-vitro pilot study.International journal of implant dentistry · 2026Article
- Metal-artifact reduced MR imaging for reverse shoulder arthroplasty: findings 1 year after surgery.Skeletal radiology · 2026Article
- Combined MRI features to assess periprosthetic hip joint infection with STIR SEMAC and MAVRIC at 1.5 T.Skeletal radiology · 2026Article
- Acceleration of slice encoding for metal artifact correction at 0.55 T using hexagonal sampling.Magnetic resonance in medicine · 2026Article
- Failure Modes in Orthopedic Oncologic Reconstructive Surgery: A Review of Imaging Findings and Failure Rates.Current oncology (Toronto, Ont.) · 2024Review
- Managing hardware-related metal artifacts in MRI: current and evolving techniques.Skeletal radiology · 2024Review
- Modern acceleration in musculoskeletal MRI: applications, implications, and challenges.Skeletal radiology · 2024Review
- Selective MR neurography-guided lumbosacral plexus perineural injections: techniques, targets, and territories.Skeletal radiology · 2023Review
- MRI-guided sacroiliac joint injections in children and adults: current practice and future developments.Skeletal radiology · 2023Review
- Advances in Bone Joint Imaging-Metal Artifact Reduction.Diagnostics (Basel, Switzerland) · 2022Review
- Review
- Performance of PROPELLER FSE TScientific reports · 2022Article
- Impact of stem design and cementation on postoperative femoral antetorsion in 227 patients with total hip arthroplasty (THA).Skeletal radiology · 2020Article
- Diagnostic interchangeability of deep convolutional neural networks reconstructed knee MR images: preliminary experience.Quantitative imaging in medicine and surgery · 2020Article
- MRI with state-of-the-art metal artifact reduction after total hip arthroplasty: periprosthetic findings in asymptomatic and symptomatic patients.European radiology · 2020Article
- [Metallic Artifacts on MR Imaging and Methods for Their Reduction].Taehan Yongsang Uihakhoe chi · 2020Review
- Metal artifact reduction MRI of total ankle arthroplasty implants.European radiology · 2018Article
- High-resolution metal artifact reduction MR imaging of the lumbosacral plexus in patients with metallic implants.Skeletal radiology · 2017Article
- Limb salvage reconstruction: Radiologic features of common reconstructive techniques and their complications.Journal of orthopaedicsReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveCompressed sensing (CS) acceleration has been theorized for slice encoding for metal artifact correction (SEMAC), but has not been shown to be feasible. Therefore, we tested the hypothesis that CS-SEMAC is feasible for MRI of metal-on-metal hip resurfacing implants. MATERIALS AND
methodsFollowing prospective institutional review board approval, 22 subjects with metal-on-metal hip resurfacing implants underwent 1.5 T MRI. We compared CS-SEMAC prototype, high-bandwidth TSE, and SEMAC sequences with acquisition times of 4-5, 4-5 and 10-12 min, respectively. Outcome measures included bone-implant interfaces, image quality, periprosthetic structures, artifact size, and signal- and contrast-to-noise ratios (SNR and CNR). Using Friedman, repeated measures analysis of variances, and Cohen's weighted kappa tests, Bonferroni-corrected p-values of 0.005 and less were considered statistically significant.
resultsThere was no statistical difference of outcomes measures of SEMAC and CS-SEMAC images. Visibility of implant-bone interfaces and pseudocapsule as well as fat suppression and metal reduction were "adequate" to "good" on CS-SEMAC and "non-diagnostic" to "adequate" on high-BW TSE (p < 0.001, respectively). SEMAC and CS-SEMAC showed mild blur and ripple artifacts. The metal artifact size was 63 % larger for high-BW TSE as compared to SEMAC and CS-SEMAC (p < 0.0001, respectively). CNRs were sufficiently high and statistically similar, with the exception of CNR of fluid and muscle and CNR of fluid and tendon, which were higher on intermediate-weighted high-BW TSE (p < 0.005, respectively).
conclusionCompressed sensing acceleration enables the time-neutral use of SEMAC for MRI of metal-on-metal hip resurfacing implants when compared to high-BW TSE and image quality similar to conventional SEMAC.
Indexed as
Identifiers
27497594What OpenQuestion holds
Registered trials