Evidence map›Paper›PMID 27495350›Full record

ArticleAnnals of biomedical engineering2017

Design Considerations of a Fiber Optic Pressure Sensor Protective Housing for Intramuscular Pressure Measurements.

Shanette A Go, Elisabeth R Jensen, Shawn M O'Connor, Loribeth Q Evertz, Duane A Morrow, Samuel R Ward, Richard L Lieber, Kenton R Kaufman

Abstract read
In one paragraph

Article in Annals of biomedical engineering, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.2field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 16 citations in OpenAlex.

  1. A framework for quantifying the mechanics of dexterous grasp.bioRxiv : the preprint server for biology · 2026
    Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Shanette A GoMayo Graduate School, Mayo Clinic, Rochester, MN, USA.
Elisabeth R JensenMayo Graduate School, Mayo Clinic, Rochester, MN, USA.
Shawn M O'ConnorDepartment of Orthopaedic Surgery, University of California at San Diego, La Jolla, CA, USA.
Loribeth Q EvertzMayo Graduate School, Mayo Clinic, Rochester, MN, USA.
Duane A MorrowDepartment of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA.
Samuel R WardDepartment of Orthopaedic Surgery, University of California at San Diego, La Jolla, CA, USA.
Richard L LieberDepartment of Orthopaedic Surgery, University of California at San Diego, La Jolla, CA, USA.
Kenton R KaufmanDepartment of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA. kaufman.kenton@mayo.edu.
Mayo Clinic in Arizona · USUniversity of California, San Diego · USShirley Ryan AbilityLab · US

Funding

Musculoskeletal Research Training ProgramT32AR056950 · NIAMS · MAYO CLINIC ROCHESTER · PI Jennifer J Westendorf · 2009 to 2026
$7.0M
MICROSENSOR FOR INTRAMUSCULAR PRESSURE MEASUREMENTR01HD031476 · NICHD · MAYO CLINIC ROCHESTER · PI KAUFMAN, KENTON R. · 1994 to 2014
$5.3M
Direct Evaluation of Muscle Strength and Motor Control Properties in AgingF30AG050390 · NIA · MAYO CLINIC ROCHESTER · PI GO, SHANETTE A · 2015 to 2018
$130k
NIAMS NIH HHS T32 AR056950NIA NIH HHS F30 AG050390NICHD NIH HHS R01 HD031476
6 · The paper itself

Abstract

Intramuscular pressure (IMP), defined as skeletal muscle interstitial fluid pressure, reflects changes in individual muscle tension and may provide crucial insight into musculoskeletal biomechanics and pathologies. IMP may be measured using fiber-optic fluid pressure sensors, provided the sensor is adequately anchored to and shielded from surrounding muscle tissue. Ineffective anchoring enables sensor motion and inadequate shielding facilitates direct sensor-tissue interaction, which result in measurement artifacts and force-IMP dissociation. The purpose of this study was to compare the effectiveness of polyimide and nitinol protective housing designs to anchor pressure sensors to muscle tissue, prevent IMP measurement artifacts, and optimize the force-IMP correlation. Anchoring capacity was quantified as force required to dislodge sensors from muscle tissue. Force-IMP correlations and non-physiological measurement artifacts were quantified during isometric muscle activations of the rabbit tibialis anterior. Housing structural integrity was assessed after both anchoring and activation testing. Although there was no statistically significant difference in anchoring capacity, nitinol housings demonstrated greater structural integrity and superior force-IMP correlations. Further design improvements are needed to prevent tissue accumulation in the housing recess associated with artificially high IMP measurements. These findings emphasize fundamental protective housing design elements crucial for achieving reliable IMP measurements.

Indexed as

Fiber Optic TechnologyPressureAnimalsFemaleIsometric ContractionMuscle, SkeletalRabbitsForceIsometric activationMicrosensorSkeletal muscleTibialis anterior

Identifiers

PMID27495350
PMCPMC5292313
OpenAlexW2481327481

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.