Evidence map›Paper›PMID 27494075›Full record

SynthesisThe Cochrane database of systematic reviews2016

D-dimer test for excluding the diagnosis of pulmonary embolism.

Fay Crawford, Alina Andras, Karen Welch, Karen Sheares, David Keeling, Francesca M Chappell

Open access · greenAbstract readMeta-AnalysisSystematic Review
In one paragraph

Synthesis in The Cochrane database of systematic reviews, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 79 papers, 3 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
79citing papers in PubMed, 3 pooled it
11.1field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

79 citing papers in PubMed, 3 syntheses or guidelines pooled it, 182 citations in OpenAlex.

  1. Pooled it
  2. D-dimer test for excluding the diagnosis of pulmonary embolism.The Cochrane database of systematic reviews · 2016
    Pooled it
  3. Pooled it
  4. Article
  5. Review
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Review
  13. Pulmonary embolism consensus.Archivos de cardiologia de Mexico · 2026
    Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article

19 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors at 6 institutions in 1 country.

Fay CrawfordNHS Fife, Queen Margaret Hospital, Dunfermline, UK, KY12 0SU.
Alina Andras
Karen Welch
Karen Sheares
David Keeling
Francesca M Chappell
Churchill Hospital · GBKeele University · GBNHS Fife · GBPapworth Hospital NHS Foundation Trust · GBUniversity of Edinburgh · GBWestern General Hospital · GB

Funding

Chief Scientist Office CZB/4/788Chief Scientist Office ETM/442Department of Health 10/4001/14Department of Health 13/89/23
6 · The paper itself

Abstract

backgroundPulmonary embolism (PE) can occur when a thrombus (blood clot) travels through the veins and lodges in the arteries of the lungs, producing an obstruction. People who are thought to be at risk include those with cancer, people who have had a recent surgical procedure or have experienced long periods of immobilisation and women who are pregnant. The clinical presentation can vary, but unexplained respiratory symptoms such as difficulty breathing, chest pain and an increased respiratory rate are common.D-dimers are fragments of protein released into the circulation when a blood clot breaks down as a result of normal body processes or with use of prescribed fibrinolytic medication. The D-dimer test is a laboratory assay currently used to rule out the presence of high D-dimer plasma levels and, by association, venous thromboembolism (VTE). D-dimer tests are rapid, simple and inexpensive and can prevent the high costs associated with expensive diagnostic tests.

objectivesTo investigate the ability of the D-dimer test to rule out a diagnosis of acute PE in patients treated in hospital outpatient and accident and emergency (A&E) settings who have had a pre-test probability (PTP) of PE determined according to a clinical prediction rule (CPR), by estimating the accuracy of the test according to estimates of sensitivity and specificity. The review focuses on those patients who are not already established on anticoagulation at the time of study recruitment. SEARCH

methodsWe searched 13 databases from conception until December 2013. We cross-checked the reference lists of relevant studies. SELECTION CRITERIA: Two review authors independently applied exclusion criteria to full papers and resolved disagreements by discussion.We included cross-sectional studies of D-dimer in which ventilation/perfusion (V/Q) scintigraphy, computerised tomography pulmonary angiography (CTPA), selective pulmonary angiography and magnetic resonance pulmonary angiography (MRPA) were used as the reference standard.•

participantsAdults who were managed in hospital outpatient and A&E settings and were suspected of acute PE were eligible for inclusion in the review if they had received a pre-test probability score based on a CPR.• INDEX TESTS: quantitative, semi quantitative and qualitative D-dimer tests.• Target condition: acute symptomatic PE.• Reference standards: We included studies that used pulmonary angiography, V/Q scintigraphy, CTPA and MRPA as reference standard tests. DATA COLLECTION AND ANALYSIS: Two review authors independently extracted data and assessed quality using Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2). We resolved disagreements by discussion. Review authors extracted patient-level data when available to populate 2 × 2 contingency tables (true-positives (TPs), true-negatives (TNs), false-positives (FPs) and false-negatives (FNs)). MAIN

resultsWe included four studies in the review (n = 1585 patients). None of the studies were at high risk of bias in any of the QUADAS-2 domains, but some uncertainty surrounded the validity of studies in some domains for which the risk of bias was uncertain. D-dimer assays demonstrated high sensitivity in all four studies, but with high levels of false-positive results, especially among those over the age of 65 years. Estimates of sensitivity ranged from 80% to 100%, and estimates of specificity from 23% to 63%. AUTHORS'

conclusionsA negative D-dimer test is valuable in ruling out PE in patients who present to the A&E setting with a low PTP. Evidence from one study suggests that this test may have less utility in older populations, but no empirical evidence was available to support an increase in the diagnostic threshold of interpretation of D-dimer results for those over the age of 65 years.

Indexed as

Acute DiseaseAdultBiomarkersCross-Sectional StudiesFalse Negative ReactionsFalse Positive ReactionsFibrin Fibrinogen Degradation ProductsHumansPulmonary EmbolismReference StandardsVenous ThromboembolismBiomarkersFibrin Fibrinogen Degradation Productsfibrin fragment D

Identifiers

PMID27494075
PMCPMC6457638
OpenAlexW1952025755

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.