Evidence map›Paper›PMID 27491407›Full record

ArticleBMC ophthalmology2016

Visualization of precut DSAEK and pre-stripped DMEK donor corneas by intraoperative optical coherence tomography using the RESCAN 700.

Akira Kobayashi, Hideaki Yokogawa, Natsuko Mori, Kazuhisa Sugiyama

Open access · goldAbstract read
In one paragraph

Article in BMC ophthalmology, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
2.6field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 24 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Review
  5. Article
  6. Review
  7. Review
  8. Review
  9. Article
  10. Article
  11. Review
  12. Review
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Akira KobayashiDepartment of Ophthalmology, Kanazawa University Graduate School of Medical Science, 13-1 Takara-machi, Kanazawa-shi, Ishikawa-ken, 920-8641, Japan. kobaya@kenroku.kanazawa-u.ac.jp.
Hideaki YokogawaDepartment of Ophthalmology, Kanazawa University Graduate School of Medical Science, 13-1 Takara-machi, Kanazawa-shi, Ishikawa-ken, 920-8641, Japan.
Natsuko MoriDepartment of Ophthalmology, Kanazawa University Graduate School of Medical Science, 13-1 Takara-machi, Kanazawa-shi, Ishikawa-ken, 920-8641, Japan.
Kazuhisa SugiyamaDepartment of Ophthalmology, Kanazawa University Graduate School of Medical Science, 13-1 Takara-machi, Kanazawa-shi, Ishikawa-ken, 920-8641, Japan.
Kanazawa University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTo report the feasibility of intraoperative spectral domain optical coherence tomography (OCT) using the RESCAN 700 for the visualization and evaluation of precut Descemet's stripping automated endothelial keratoplasty (DSAEK) and prestripped Descemet's membrane endothelial keratoplasty (DMEK) donor tissue.

methodsPrecut DSAEK (n = 11), prestripped DMEK (n = 4) preserved in a viewing chamber were examined by intraoperative OCT. Wholly intact donor corneas for penetrating keratoplasty (PK) (n = 8) were also examined as controls. The obtained images were analyzed qualitatively for characteristics of each type of donor.

resultsFor each type of donor, characteristic images were consistently obtained by intraoperative OCT in both the front and back views through the viewing chamber. In wholly intact donors for PK, appearance of normal corneal curvature and stromal texture with high reflectivity of epithelium and endothelium cell layers were clearly visualized. In precut DSAEK donors, precut lines were characteristically visualized in addition to the intact donor cornea images. In prestripped DMEK donors, identical OCT images to the intact donor cornea were noted when observed from the anterior surface. However, peripheral partial detachments of Descemet's membrane were characteristically observed in all prestripped DMEK donors when viewed from the back of the viewing chamber.

conclusionRapid visualization and rough evaluation of donor tissues for PK, precut DSAEK and prestripped DMEK donor corneas by intraoperative OCT was consistently possible through the viewing chamber. Therefore, this device may be used as an alternative of AS-OCT when the eyebank does not have their own AS-OCT. Although the peripheral detachment in DMEK donors are quite common and clinically non-problematic in DMEK donor quality and subsequent DMEK surgeries, it may be useful to distinguish between wholly intact PK donors and prestripped DMEK donors, enabling to prevent mix-ups of donors, especially when several different types of keratoplasties are scheduled in a same day in one operating theater.

Indexed as

Tissue and Organ HarvestingCorneal DiseasesDescemet MembraneDescemet Stripping Endothelial KeratoplastyEndothelium, CornealFeasibility StudiesHumansIntraoperative PeriodKeratoplasty, PenetratingTissue DonorsTomography, Optical CoherenceDescemet’s membrane endothelial keratoplastyDescemet’s stripping automated endothelial keratoplastyIntraoperative OCTRESCAN 700

Identifiers

PMID27491407
PMCPMC4973550
OpenAlexW2481535557

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.