Evidence map›Paper›PMID 27490807›Full record

ArticleBritish journal of cancer2016

Digital vs screen-film mammography in population-based breast cancer screening: performance indicators and tumour characteristics of screen-detected and interval cancers.

Linda de Munck, Geertruida H de Bock, Renée Otter, Dick Reiding, Mireille Jm Broeders, Pax Hb Willemse, Sabine Siesling

Abstract read
In one paragraph

Article in British journal of cancer, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Review
  5. Article
  6. [Digital Mammography as a Screening Tool in Korea].Taehan Yongsang Uihakhoe chi · 2021
    Review
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Calcifications at Digital Breast Tomosynthesis: Imaging Features and Biopsy Techniques.Radiographics : a review publication of the Radiological Society of North America, Inc
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Linda de MunckDepartment of Research, Netherlands Comprehensive Cancer Organisation, PO Box 19079, Utrecht 3501 DB, The Netherlands.
Geertruida H de BockDepartment of Epidemiology, University of Groningen, University Medical Center Groningen, PO Box 30001, Groningen 9700 RB, The Netherlands.
Renée OtterDepartment of Research, Netherlands Comprehensive Cancer Organisation, PO Box 19079, Utrecht 3501 DB, The Netherlands.
Dick ReidingNational Cancer Screening Programme, region North, PO Box 425, Groningen 9700 AK, The Netherlands.
Mireille Jm BroedersRadboud Institute for Health Sciences, Radboud University Medical Center, PO Box 9101, Nijmegen 6500 HB, The Netherlands.
Pax Hb WillemseDepartment of Medical Oncology, University of Groningen, University Medical Center Groningen, PO Box 30001, Groningen 9700 RB, The Netherlands.
Sabine SieslingDepartment of Research, Netherlands Comprehensive Cancer Organisation, PO Box 19079, Utrecht 3501 DB, The Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundFull-field digital mammography (FFDM) has replaced screen-film mammography (SFM) in most breast cancer screening programs due to technological advantages such as possibilities to adjust contrast, better image quality and transfer capabilities. This study describes the performance indicators during the transition from SFM to FFDM and the characteristics of screen-detected and interval cancers.

methodsData of the Dutch breast cancer screening program, region North from 2004 to 2010 were linked to The Netherlands Cancer Registry (N=902 868). Performance indicators and tumour characteristics of screen-detected and interval cancers were compared between FFDM and SFM.

resultsAfter initial screens, recall rates were 2.1% (SFM) and 3.0% (FFDM; P<0.001). The positive predictive values (PPV) were 25.6% (SFM) and 19.9% (FFDM; P=0.002). Detection rates were similar, as were all performance indicators after subsequent screens. Similar percentages of low-grade ductal carcinoma in situ (DCIS) were found for SFM and FFDM. Invasive cancers diagnosed after subsequent screens with FFDM were more often of high-grade (P=0.024) and ductal type (P=0.030). The incidence rates of interval cancers were similar for SFM and FFDM after initial (2.69/1000 vs 2.51/1000; P=0.787) and subsequent screens (2.30 vs 2.41; P=0.652), with similar tumour characteristics.

conclusionsFFDM resulted in similar rates of screen-detected and interval cancers, indicating that FFDM performs as well as SFM in a breast cancer screening program. No signs of an increase in low-grade DCIS (which might connote possible overdiagnosis) were seen. Nonetheless, after initial screening, which accounts for 12% of all screens, FFDM resulted in higher recall rate and lower PPV that requires attention.

Indexed as

AgedBreast NeoplasmsFemaleHumansMammographyMiddle AgedNetherlands

Identifiers

PMID27490807
PMCPMC4997549

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.