In one paragraph

Article in The international journal of medical robotics + computer assisted surgery : MRCAS, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. FBG-based Shape-Sensing to Enable Lateral Deflection Methods of Autonomous Needle Insertion.Proceedings of the ... IEEE/RSJ International Conference on Intelligent Robots and Systems. IEEE/RSJ International Conference on Intelligent Robots and Systems · 2024
    Article
  2. Article
  3. Article
  4. Article
  5. Concepts and Trends n Autonomy for Robot-Assisted Surgery.Proceedings of the IEEE. Institute of Electrical and Electronics Engineers · 2022
    Article
  6. Remotely Actuated Needle Driving Device for MRI-Guided Percutaneous Interventions.... International Symposium on Medical Robotics. International Symposium on Medical Robotics · 2019
    Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Meng LiSchool of Mechatronical Engineering, Beijing Institute of Technology, Beijing, China.ORCID http://orcid.org/0000-0003-3648-7917
Gang Li100 Institute Road, Worcester Polytechnic Institute, Worcester, MA, USA.
Berk GonencHackerman 200, Johns Hopkins University, Baltimore, MD, USA.
Xingguang DuanSchool of Mechatronical Engineering, Beijing Institute of Technology, Beijing, China.
Iulian IordachitaHackerman 200, Johns Hopkins University, Baltimore, MD, USA.

Funding

Enabling Technologies for MRI-Guided Prostate InterventionsR01CA111288 · NCI · BRIGHAM AND WOMEN'S HOSPITAL · PI TEMPANY, CLARE M · 2006 to 2015
$7.8M
NCI NIH HHS R01 CA111288
6 · The paper itself

Abstract

backgroundAccurate needle placement into soft tissue is essential to percutaneous prostate cancer diagnosis and treatment procedures.

methodsThis paper discusses the steering of a 20 gauge (G) FBG-integrated needle with three sets of Fiber Bragg Grating (FBG) sensors. A fourth-order polynomial shape reconstruction method is introduced and compared with previous approaches. To control the needle, a bicycle model based navigation method is developed to provide visual guidance lines for clinicians. A real-time model updating method is proposed for needle steering inside inhomogeneous tissue. A series of experiments were performed to evaluate the proposed needle shape reconstruction, visual guidance and real-time model updating methods.

resultsTargeting experiments were performed in soft plastic phantoms and in vitro tissues with insertion depths ranging between 90 and 120 mm. Average targeting errors calculated based upon the acquired camera images were 0.40 ± 0.35 mm in homogeneous plastic phantoms, 0.61 ± 0.45 mm in multilayer plastic phantoms and 0.69 ± 0.25 mm in ex vivo tissue.

conclusionsResults endorse the feasibility and accuracy of the needle shape reconstruction and visual guidance methods developed in this work. The approach implemented for the multilayer phantom study could facilitate accurate needle placement efforts in real inhomogeneous tissues. Copyright © 2016 John Wiley & Sons, Ltd.

Indexed as

Man-Machine SystemsNeedlesComputer SystemsEquipment DesignEquipment Failure AnalysisFeedbackHumansImage-Guided BiopsyInjectionsMagnetic Resonance Imaging, InterventionalMicro-Electrical-Mechanical SystemsPhantoms, ImagingRefractometryReproducibility of ResultsRoboticsSensitivity and SpecificityFBG sensormultilayer phantom insertionneedle steeringprostate intervention