ArticlePediatric research2016
Assessment of pedometer accuracy in capturing habitual types of physical activities in overweight and obese children.
Article in Pediatric research, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Step and Distance Measurement From a Low-Cost Consumer-Based Hip and Wrist Activity Monitor: Protocol for a Validity and Reliability Assessment.JMIR research protocols · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundCurrently, there is a limited amount of research exploring physical activity measurement tools in overweight and obese (OW/OB) children using pedometers. Thus, our objective was to determine the accuracy of one spring-levered (SC-T2) and two piezoelectric pedometers (NL-1000 and Piezo) in OW/OB children.
methodsA total of 26 boys and 34 girls (n = 60) participated. Pedometer step-counts were compared to observed step counts for walking (walking, stair ascent and decent) and hopping tests. Pedometer accuracies were compared with Friedman tests while Bland-Altman plots were used to establish the accuracy of each pedometer against direct observations.
resultsBoys (n = 26) and females (n = 34) were 96 and 91% OB, respectively. The two piezoelectric pedometers (NL-1000 and Piezo) were accurate for walking and stair climbing tasks, however all pedometers were inaccurate for hopping tests. Averaged over all three walking activities, the NL-1000 was the most accurate with 6.7% median error (interquartile range (IQR): 0.0-13.3); followed by the Piezo with 10.0% median error (IQR: 3.3-18.1); SC-T2 was the least accurate with -14.7% median error (IQR: -54.8-3.5).
conclusionThese results support the use of the piezoelectric pedometers for walking and stair climbing types of activities, which are typical for OW/OB children in a nonlaboratory setting.
Indexed as
Identifiers
27486704What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.