Evidence map›Paper›PMID 27465636›Full record

ArticleScientific reports2016

Magnetic Resonance Imaging of Phosphocreatine and Determination of BOLD Kinetics in Lower Extremity Muscles using a Dual-Frequency Coil Array.

Ryan Brown, Oleksandr Khegai, Prodromos Parasoglou

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed, 1 pooled it
0.9field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 1 synthesis or guideline pooled it, 18 citations in OpenAlex.

  1. NMR in biomedicine · 2025
    Pooled it
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Simultaneous TMagnetic resonance in medicine · 2021
    Article
  8. High-Resolution DynamicIEEE transactions on bio-medical engineering · 2020
    Article
  9. Article
  10. A dual-tunedMagnetic resonance in medicine · 2020
    Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Ryan BrownBernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, NY, USA.
Oleksandr KhegaiBernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, NY, USA.
Prodromos ParasoglouBernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, NY, USA.
New York University · USAdvanced Imaging Research (United States) · US

Funding

TR&D 4: Revealing Microstructure: Biophysical modeling and validation for discovery and clinical careP41EB017183 · NIBIB · NEW YORK UNIVERSITY SCHOOL OF MEDICINE · PI Christopher M Collins · 2014 to 2026
$19.3M
Multinuclear MRI Assessment of Diabetic Peripheral NeuropathyR01DK106292 · NIDDK · NEW YORK UNIVERSITY SCHOOL OF MEDICINE · PI BROWN, RYAN · 2015 to 2018
$1.7M
NIBIB NIH HHS P41 EB017183NIDDK NIH HHS R01 DK106292
6 · The paper itself

Abstract

Magnetic resonance imaging (MRI) provides the unique ability to study metabolic and microvasculature functions in skeletal muscle using phosphorus and proton measurements. However, the low sensitivity of these techniques can make it difficult to capture dynamic muscle activity due to the temporal resolution required for kinetic measurements during and after exercise tasks. Here, we report the design of a dual-nuclei coil array that enables proton and phosphorus MRI of the human lower extremities with high spatial and temporal resolution. We developed an array with whole-volume coverage of the calf and a phosphorus signal-to-noise ratio of more than double that of a birdcage coil in the gastrocnemius muscles. This enabled the local assessment of phosphocreatine recovery kinetics following a plantar flexion exercise using an efficient sampling scheme with a 6 s temporal resolution. The integrated proton array demonstrated image quality approximately equal to that of a clinical state-of-the-art knee coil, which enabled fat quantification and dynamic blood oxygen level-dependent measurements that reflect microvasculature function. The developed array and time-efficient pulse sequences were combined to create a localized assessment of calf metabolism using phosphorus measurements and vasculature function using proton measurements, which could provide new insights into muscle function.

Indexed as

AdultEquipment DesignHumansIsometric ContractionKineticsMagnetic Resonance ImagingMaleMuscle, SkeletalPhosphocreatineSignal-To-Noise RatioPhosphocreatine

Identifiers

PMID27465636
PMCPMC4964597
OpenAlexW2484236462

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked