ArticleBiomedical microdevices2016
Assessment of whole blood thrombosis in a microfluidic device lined by fixed human endothelium.
Article in Biomedical microdevices, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 76 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
76 citing papers in PubMed, 1 synthesis or guideline pooled it, 140 citations in OpenAlex.
- Neosinus and Valve Thrombosis After Transcatheter Aortic Valve Replacement.Journal of the American Heart Association · 2026Pooled it
- Enabling Technologies in Vascular Biology: Microphysiological Systems, Organoids, and Beyond.Arteriosclerosis, thrombosis, and vascular biology · 2026Review
- Hemadyne: accordion-inspired perfusion for microphysiological systems.Nature communications · 2026Article
- Investigational New Drug-enabling studies in a human vessel-chip: Are we there yet?Bioengineering & translational medicine · 2026Review
- Microfluidic Chip Platforms for Red Blood Cell Storage Lesion Quality Control and Precision Transfusion.Research (Washington, D.C.) · 2026Review
- Biophysical perspectives of the spatiotemporal dynamics of plasma coagulation under flow.Biophysical reviews · 2025Review
- Microfluidic platforms for monitoring cardiomyocyte electromechanical activity.Microsystems & nanoengineering · 2025Review
- Design strategy primer for organ-on-chips.Biomaterials translational · 2025Article
- Rapid Biofabrication of an Advanced Microphysiological System Mimicking Phenotypical Heterogeneity and Drug Resistance in Glioblastoma.Advanced healthcare materials · 2024Article
- Transformation gap from research findings to large-scale commercialized products in microfluidic field.Materials today. Bio · 2024Review
- A Potential Role for MAGI-1 in the Bi-Directional Relationship Between Major Depressive Disorder and Cardiovascular Disease.Current atherosclerosis reports · 2024Review
- Clot Accumulation in 3D Microfluidic Bifurcating Microvasculature Network.Micromachines · 2024Article
- Integrating Computational and Biological Hemodynamic Approaches to Improve Modeling of Atherosclerotic Arteries.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024Review
- Angiogenesis-Enabled Human Ovarian Tumor Microenvironment-Chip Evaluates Pathophysiology of Platelets in Microcirculation.Advanced healthcare materials · 2024Article
- Vascular dysfunction in hemorrhagic viral fevers: opportunities for organotypic modeling.Biofabrication · 2024Review
- Considering future qualification for regulatory science in the early development of microphysiological systems: a case study of microthrombosis in a Vessel-on-Chip.Frontiers in toxicology · 2024Article
- Embedded macrophages induce intravascular coagulation in 3D blood vessel-on-chip.Biomedical microdevices · 2023Article
- Engineering Organ-on-a-Chip Systems for Vascular Diseases.Arteriosclerosis, thrombosis, and vascular biology · 2023Review
- The prospects of microphysiological systems in modeling platelet pathophysiology in cancer.Platelets · 2023Review
- Fluid flow to mimic organ function in 3DAPL bioengineering · 2023Review
16 more citing papers are in PubMed but not listed here.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors at 6 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The vascular endothelium and shear stress are critical determinants of physiological hemostasis and platelet function in vivo, yet current diagnostic and monitoring devices do not fully incorporate endothelial function under flow in their assessment and, therefore, they can be unreliable and inaccurate. It is challenging to include the endothelium in assays for clinical laboratories or point-of-care settings because living cell cultures are not sufficiently robust. Here, we describe a microfluidic device that is lined by a human endothelium that is chemically fixed, but still retains its ability to modulate hemostasis under continuous flow in vitro even after few days of storage. This device lined with a fixed endothelium supports formation of platelet-rich thrombi in the presence of physiological shear, similar to a living arterial vessel. We demonstrate the potential clinical value of this device by showing that thrombus formation and platelet function can be measured within minutes using a small volume (0.5 mL) of whole blood taken from subjects receiving antiplatelet medications. The inclusion of a fixed endothelial microvessel will lead to biomimetic analytical devices that can potentially be used for diagnostics and point-of-care applications.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials