Evidence map›Paper›PMID 27459377›Full record

ArticlePloS one2016

The Spatiotemporal Stability of Dominant Frequency Sites in In-Silico Modeling of 3-Dimensional Left Atrial Mapping of Atrial Fibrillation.

Changyong Li, Byounghyun Lim, Minki Hwang, Jun-Seop Song, Young-Seon Lee, Boyoung Joung, Hui-Nam Pak

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
2.5field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 23 citations in OpenAlex.

  1. Trial
  2. Trial
  3. Trial
  4. Role of Computational Modelling in Enhancing Thermal Safety During Cardiac Ablation.Interdisciplinary cardiovascular and thoracic surgery · 2025
    Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Computational models in cardiology.Nature reviews. Cardiology · 2019
    Review
  12. Article
  13. Article
  14. Article
  15. VirtualFrontiers in physiology · 2017
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Changyong LiYonsei University Health System, Seoul, Republic of Korea.
Byounghyun LimYonsei University Health System, Seoul, Republic of Korea.
Minki HwangYonsei University Health System, Seoul, Republic of Korea.
Jun-Seop SongYonsei University Health System, Seoul, Republic of Korea.
Young-Seon LeeYonsei University Health System, Seoul, Republic of Korea.
Boyoung JoungYonsei University Health System, Seoul, Republic of Korea.
Hui-Nam PakYonsei University Health System, Seoul, Republic of Korea.
Yonsei University Health System · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundWe previously reported that stable rotors were observed in in-silico human atrial fibrillation (AF) models, and were well represented by dominant frequency (DF). We explored the spatiotemporal stability of DF sites in 3D-AF models imported from patient CT images of the left atrium (LA).

methodsWe integrated 3-D CT images of the LA obtained from ten patients with persistent AF (male 80%, 61.8 ± 13.5 years old) into an in-silico AF model. After induction, we obtained 6 seconds of AF simulation data for DF analyses in 30 second intervals (T1-T9). The LA was divided into ten sections. Spatiotemporal changes and variations in the temporal consistency of DF were evaluated at each section of the LA. The high DF area was defined as the area with the highest 10% DF.

results1. There was no spatial consistency in the high DF distribution at each LA section during T1-T9 except in one patient (p = 0.027). 2. Coefficients of variation for the high DF area were highly different among the ten LA sections (p < 0.001), and they were significantly higher in the four pulmonary vein (PV) areas, the LA appendage, and the peri-mitral area than in the other LA sections (p < 0.001). 3. When we conducted virtual ablation of 10%, 15%, and 20% of the highest DF areas (n = 270 cases), AF was changed to atrial tachycardia (AT) or terminated at a rate of 40%, 57%, and 76%, respectively.

conclusionsSpatiotemporal consistency of the DF area was observed in 10% of AF patients, and high DF areas were temporally variable. Virtual ablation of DF is moderately effective in AF termination and AF changing into AT.

Indexed as

Models, CardiovascularPatient-Specific ModelingAgedAtrial FibrillationHeart AtriaHumansMaleMiddle AgedPositron-Emission Tomography

Identifiers

PMID27459377
PMCPMC4961424
OpenAlexW2491223194

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.