Evidence map›Paper›PMID 27456818›Full record

ArticleScientific reports2016

New cosurface capacitive stimulators for the development of active osseointegrative implantable devices.

Marco P Soares Dos Santos, Ana Marote, T Santos, João Torrão, A Ramos, José A O Simões, Odete A B da Cruz E Silva, Edward P Furlani, Sandra I Vieira, Jorge A F Ferreira

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed
2.2field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed, 35 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. The application of impantable sensors in the musculoskeletal system: a review.Frontiers in bioengineering and biotechnology · 2024
    Review
  5. Sensor Technology in Fracture Healing.Indian journal of orthopaedics · 2023
    Review
  6. Article
  7. Review
  8. Article
  9. Multifunctional Smart Bone Implants: Fiction or Future?-A New Perspective.Frontiers in bioengineering and biotechnology · 2022
    Article
  10. Article
  11. Article
  12. Article
  13. Endurance testing and finite element simulation of a modified hip stem for integration of an energy harvesting system.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2021
    Article
  14. Article
  15. Review
  16. Review
  17. Article
  18. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 2 countries.

Marco P Soares Dos SantosCentre for Mechanical Technology &Automation (TEMA), University of Aveiro, Aveiro, Portugal.
Ana MaroteInstitute of Biomedicine (iBiMED), Department of Medical Sciences, University of Aveiro, Aveiro, Portugal.
T SantosPhysics Department, University of Aveiro, Aveiro, Portugal.
João TorrãoDepartment of Mechanical Engineering, University of Aveiro, Aveiro, Portugal.
A RamosCentre for Mechanical Technology &Automation (TEMA), University of Aveiro, Aveiro, Portugal.
José A O SimõesDepartment of Mechanical Engineering, University of Aveiro, Aveiro, Portugal.
Odete A B da Cruz E SilvaInstitute of Biomedicine (iBiMED), Department of Medical Sciences, University of Aveiro, Aveiro, Portugal.
Edward P FurlaniDepartment of Chemical and Biological Engineering, University at Buffalo, SUNY, Buffalo, NY, US.
Sandra I VieiraInstitute of Biomedicine (iBiMED), Department of Medical Sciences, University of Aveiro, Aveiro, Portugal.
Jorge A F FerreiraCentre for Mechanical Technology &Automation (TEMA), University of Aveiro, Aveiro, Portugal.
University of Aveiro · PTUniversity at Buffalo, State University of New York · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Non-drug strategies based on biophysical stimulation have been emphasized for the treatment and prevention of musculoskeletal conditions. However, to date, an effective stimulation system for intracorporeal therapies has not been proposed. This is particularly true for active intramedullary implants that aim to optimize osseointegration. The increasing demand for these implants, particularly for hip and knee replacements, has driven the design of innovative stimulation systems that are effective in bone-implant integration. In this paper, a new cosurface-based capacitive system concept is proposed for the design of implantable devices that deliver controllable and personalized electric field stimuli to target tissues. A prototype architecture of this system was constructed for in vitro tests, and its ability to deliver controllable stimuli was numerically analyzed. Successful results were obtained for osteoblastic proliferation and differentiation in the in vitro tests. This work provides, for the first time, a design of a stimulation system that can be embedded in active implantable devices for controllable bone-implant integration and regeneration. The proposed cosurface design holds potential for the implementation of novel and innovative personalized stimulatory therapies based on the delivery of electric fields to bone cells.

Indexed as

Prostheses and ImplantsBone DevelopmentCell DifferentiationCell ProliferationElectric StimulationFracture Fixation, IntramedullaryHumansOsseointegrationSurface Properties

Identifiers

PMID27456818
PMCPMC4960616
OpenAlexW2476150832

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.