ArticleJournal of applied clinical medical physics2016
Treatment accuracy without rotational setup corrections in intracranial SRT.
Article in Journal of applied clinical medical physics, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed.
- Coplanar versus non-coplanar volumetric modulated arc therapy for hippocampal avoidance whole brain radiotherapy using Monte Carlo-based planning system.Radiological physics and technology · 2026Article
- A retrospective study on improving the accuracy of radiotherapy for patients with breast cancer with lymph node metastasis using Styrofoam.Radiology and oncology · 2024Article
- Mask dependency of the lacrimal gland dose under whole brain radiotherapy when the six-degrees of freedom couch is not available.Journal of applied clinical medical physics · 2023Article
- Evaluation of corrective effect of 6 degree of freedom couch on setup errors in intensity modulated radiotherapy for postoperative rectal cancer patients.Frontiers in oncology · 2023Article
- A simplified non-coplanar volumetric modulated arc therapy for the whole brain radiotherapy with hippocampus avoidance.Frontiers in oncology · 2023Article
- Positioning error analysis of the fraxion localization system in the intracranial stereotactic radiotherapy of tumors.Clinical & translational oncology : official publication of the Federation of Spanish Oncology Societies and of the National Cancer Institute of Mexico · 2021Article
- The impact of isocentric shifts on delivery accuracy during the irradiation of small cerebral targets-Quantification and possible corrections.Journal of applied clinical medical physics · 2020Article
- Assessment of the use of different imaging and delivery techniques for cranial treatments on the Halcyon linac.Journal of applied clinical medical physics · 2020Article
- Clinical commissioning of a new patient positioning system, SyncTraX FX4, for intracranial stereotactic radiotherapy.Journal of applied clinical medical physics · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The aim of this study was to evaluate the impact of actual rotational setup errors on dose distributions in intracranial stereotactic radiotherapy (SRT) with different alternatives for treatment position selection. A total of 38 SRT fractions from 18patients were retrospectively evaluated with rotational setup errors obtained from actual treatments. The planning computed tomography (CT) images were rotated according to online cone-beam CT (CBCT) images and the dose distribution was recalculated to the rotated CT images using three different patient positionings derived from: 1) an automatic 6D match neglecting rotation correction (Auto6D); 2) an automatic 3D match (Auto3D); and 3) a manual 3D match from actual treatment (Treat3D). The mean conformity index (CI) was 0.92 for the original plans and 0.91 for the Auto6D plans. The mean CI decreased significantly (p < 0.01) to 0.78 and 0.80 for the Auto3D and the Treat3D plans, respectively. The mean minimum dose of the planning target volume (PTVmin) was 91.9% of the prescribed dose for the original plans and 92.1% for the Auto6D plans, while for the Auto3D and the Treat3D plans PTVmin decreased significantly (p < 0.01) to 78.9% and 80.2%, respectively. No significant differences were seen between the Auto6D and the original treatment plans in terms of the dose parameters. However, the Auto3D and the Treat3D plans were statistically significantly inferior (p < 0.01) to the Auto6D and the original plans. In addition, a significant negative correlation (p < 0.01, |r| > 0.38) was found in the Auto3D and the Treat3D cases between the rotation error and CI, PTVmin or minimum dose of gross tumour volume. In SRT, a treatment plan of comparable quality to 6D rotation correction can be achieved by using 6D registration without a rotational correction in the selection of patient positioning. This was demonstrated for typical rotation errors seen in clinical practice.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.