ArticleMagnetic resonance in medicine2016
High efficiency coronary MR angiography with nonrigid cardiac motion correction.
Article in Magnetic resonance in medicine, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed.
- Motion Mitigation Techniques for Abdominal and Cardiac MR Imaging.Journal of magnetic resonance imaging : JMRI · 2026Review
- High on sparsity: Interbin compensation of cardiac motion for improved assessment of left-ventricular function using 5D whole-heart MRI.Magnetic resonance in medicine · 2025Article
- High-resolution MRI synthesis using a data-driven framework with denoising diffusion probabilistic modeling.Physics in medicine and biology · 2024Article
- Cardiac MR: From Theory to Practice.Frontiers in cardiovascular medicine · 2022Review
- Motion compensated whole-heart coronary cardiovascular magnetic resonance angiography using focused navigation (fNAV).Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2021Article
- Coronary Magnetic Resonance Angiography in Chronic Coronary Syndromes.Frontiers in cardiovascular medicine · 2021Review
- Iterative motion-compensation reconstruction ultra-short TE (iMoCo UTE) for high-resolution free-breathing pulmonary MRI.Magnetic resonance in medicine · 2020Article
- Correcting versus resolving respiratory motion in free-breathing whole-heart MRA: a comparison in patients with thoracic aortic disease.European radiology experimental · 2019Article
- Visualization of coronary arteries in paediatric patients using whole-heart coronary magnetic resonance angiography: comparison of image-navigation and the standard approach for respiratory motion compensation.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2019Article
- Whole-heart coronary MR angiography using a 3D cones phyllotaxis trajectory.Magnetic resonance in medicine · 2019Article
- Optimized respiratory-resolved motion-compensated 3D Cartesian coronary MR angiography.Magnetic resonance in medicine · 2018Article
- Technical note: Accelerated nonrigid motion-compensated isotropic 3D coronary MR angiography.Medical physics · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
purposeTo improve the coronary visualization quality of four-dimensional (4D) coronary MR angiography (MRA) through cardiac motion correction and iterative reconstruction.
methodsA contrast-enhanced, spoiled gradient echo sequence with 3D radial trajectory and self-gating was used for 4D coronary MRA data acquisition at 3 Tesla. A whole-heart 16-phase cine series was reconstructed with respiratory motion correction. Nonrigid registration was performed between the identified quiescent phases and a reference. The motion information of all included phases was then used along with the corresponding k-space data to iteratively reconstruct the final image. Healthy volunteer studies (N = 13) were conducted to compare the proposed method with the conventional strategy, which accepts data from a single, contiguous window out of the original 16-phase data. Apparent signal-to-noise ratio (aSNR) and coronary sharpness were used as the image quality metrics.
resultsThe proposed method significantly improved aSNR (11.89 ± 3.76 to 13.97 ± 5.21; P = 0.005) and scan efficiency (18.8% ± 6.0% to 40.9% ± 9.7%; P < 0.001), compared with the conventional strategy. Sharpness of left main (P = 0.002), proximal (P = 0.04), and middle (P = 0.02) right coronary artery, and proximal left anterior descending (P = 0.04) was also significantly improved.
conclusionThe proposed cardiac motion-corrected reconstruction significantly improved the achievable quality of coronary visualization from 4D coronary MRA. Magn Reson Med 76:1345-1353, 2016. © 2016 International Society for Magnetic Resonance in Medicine.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.