Evidence map›Paper›PMID 27454373›Full record

ReviewShock (Augusta, Ga.)2016

Implantable Device-Related Infection.

J Scott VanEpps, John G Younger

Abstract readReview
In one paragraph

Review in Shock (Augusta, Ga.), 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 130 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
130citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

130 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Review
  5. Article
  6. Review
  7. Article
  8. Article
  9. Article
  10. Review
  11. Review
  12. Review
  13. Review
  14. Review
  15. Review
  16. Review
  17. Article
  18. Article
  19. Article
  20. Article

70 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

J Scott VanEppsDepartment of Emergency Medicine, Michigan Center for Integrative Research in Critical Care, Biointerfaces Institute, University of Michigan, Ann Arbor, Michigan.
John G Younger

Funding

Biomechanics of Blood Stream InfectionsR01GM081702 · NIGMS · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI SOLOMON, MICHAEL J · 2009 to 2017
$3.2M
NIGMS NIH HHS R01 GM081702
6 · The paper itself

Abstract

Over half of the nearly two million healthcare-associated infections can be attributed to indwelling medical devices. In this review, we highlight the difficulty in diagnosing implantable device-related infection and how this leads to a likely underestimate of the prevalence. We then provide a length-scale conceptualization of device-related infection pathogenesis. Within this conceptualization we focus specifically on biofilm formation and the role of host immune and coagulation systems. Using this framework, we describe how current and developing preventative strategies target specific processes along the entire length-scale. In light of the significant time horizon for the development and translation of new preventative technologies, we also emphasize the need for parallel development of in situ treatment strategies. Specific examples of both preventative and treatment strategies and how they align with the length-scale conceptualization are described.

Indexed as

Anti-Bacterial AgentsBacterial InfectionsBiofilmsProstheses and ImplantsAnti-Bacterial Agents

Identifiers

PMID27454373
PMCPMC5110396

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.