Mammography in females with an implanted medical device: impact on image quality, pain and anxiety.

Ellen Paap, Marloes Witjes, Cary van Landsveld-Verhoeven, Ruud M Pijnappel, Angela H E M Maas, Mireille J M Broeders

Open access · greenAbstract read
In one paragraph

Article in The British journal of radiology, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
0.8field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 25 citations in OpenAlex.

  1. Trial
  2. Review
  3. Review
  4. Feasibility, safety, and comfort of the '2BB' (2 cm below the bra) position of insertable cardiac monitors in women: the IN-WOMEN-ICM pilot study.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2024
    Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Ellen Paap1 Dutch Reference Centre for Screening, Nijmegen, Netherlands.
Marloes Witjes1 Dutch Reference Centre for Screening, Nijmegen, Netherlands.
Cary van Landsveld-Verhoeven1 Dutch Reference Centre for Screening, Nijmegen, Netherlands.
Ruud M Pijnappel1 Dutch Reference Centre for Screening, Nijmegen, Netherlands.
Angela H E M Maas3 Department of Cardiology, Radboud University Medical Center, Nijmegen, Netherlands.
Mireille J M Broeders1 Dutch Reference Centre for Screening, Nijmegen, Netherlands.
Dutch Expert Centre for Screening · NLRadboud University Medical Center · NLUniversity Medical Center Utrecht · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo assess the image quality of mammograms in females with an implanted medical device (IMD), to evaluate pain and anxiety during mammography in these females and to investigate the experience of radiographers.

methodsImage quality was evaluated by two radiographers and one radiologist in the images of females with an IMD participating in the Dutch screening programme (clients). Pain and anxiety were scored using a Numeric Rating Scale in both clients visiting a screening organization and patients from the Isala Hospital, Zwolle. Experience of screening radiographers was collected with a questionnaire.

resultsImages of the breast with IMD showed reduced contrast in craniocaudal (CC) and mediolateral-oblique (MLO) views [by both the radiographers and radiologist (range: 11-29%)], less projected breast tissue [only radiographers; CC lateral side: 25.5%, 95% confidence interval (CI): 18.7-32.2] and reduced projection of the pectoral muscle (only radiographers; MLO width pectoral muscle: 31.5%, 95% CI: 24.4-38.7). Clients experienced more pain and anxiety during mammography in the breast with IMD compared to the breast without IMD in the breast (pain difference CC: 0.48 ± 0.16, p = 0.003; pain difference MLO: 0.46 ± 0.16, p = 0.004; anxiety difference 1.30 ± 0.22; p < 0.001). Patients experienced more pain (1.05 ± 0.12; p < 0.001) and anxiety (1.22 ± 0.15; p < 0.001) after placement of IMD. Radiographers are more cautious, more anxious and use less compression during mammography of breasts with IMD.

conclusionImage quality in a breast with an IMD could be improved by projecting more breast tissue on the mammogram, thereby including (part of) the IMD between the paddles, if required. In addition, radiographers should pay sufficient attention to reducing discomfort both before and during the screening examination. ADVANCES IN KNOWLEDGE: Little is known about the quality of mammography in females with an IMD or how these females and radiographers experience the screening examination. The results of our study showed that having an IMD could result in a suboptimal mammogram and increased discomfort.

Indexed as

Prostheses and ImplantsAgedAnxietyBreast NeoplasmsFemaleHumansMammographyMiddle AgedNetherlandsPain ManagementPain MeasurementQuality ImprovementSurveys and Questionnaires

Identifiers

PMID27452263
PMCPMC5124797
OpenAlexW2491330051

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.