Evidence map›Paper›PMID 27447529›Full record

ArticlePhysical review letters2016

Virtual k-Space Modulation Optical Microscopy.

Cuifang Kuang, Ye Ma, Renjie Zhou, Guoan Zheng, Yue Fang, Yingke Xu, Xu Liu, Peter T C So

Abstract read
In one paragraph

Article in Physical review letters, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Review
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Cuifang KuangState Key Laboratory of Modern Optical Instrumentation, College of Optical Science and Engineering, Zhejiang University, Hangzhou 310027, China.
Ye MaState Key Laboratory of Modern Optical Instrumentation, College of Optical Science and Engineering, Zhejiang University, Hangzhou 310027, China.
Renjie ZhouLaser Biomedical Research Center, G. R. Harrison Spectroscopy Laboratory, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA.
Guoan ZhengDepartment of Biomedical Engineering, University of Connecticut, Storrs, Connecticut 06269, USA.
Yue FangState Key Laboratory of Modern Optical Instrumentation, College of Optical Science and Engineering, Zhejiang University, Hangzhou 310027, China.
Yingke XuKey Laboratory of Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, Zhejiang University, Hangzhou 310027, China.
Xu LiuState Key Laboratory of Modern Optical Instrumentation, College of Optical Science and Engineering, Zhejiang University, Hangzhou 310027, China.
Peter T C SoDepartment of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA.

Funding

Wide-Field Short-Wave Infrared (SWIR) multiphoton (MP) tissue imagingP41EB015871 · NIBIB · MASSACHUSETTS INSTITUTE OF TECHNOLOGY · PI SO, PETER T. · 2012 to 2021
$11.3M
Characterizing mechanisms of sickle cell crisis via dynamic optical assayR01HL121386 · NHLBI · MASSACHUSETTS INSTITUTE OF TECHNOLOGY · PI SO, PETER T. · 2014 to 2016
$1.7M
NHLBI NIH HHS R01 HL121386NIBIB NIH HHS P41 EB015871
6 · The paper itself

Abstract

We report a novel superresolution microscopy approach for imaging fluorescence samples. The reported approach, termed virtual k-space modulation optical microscopy (VIKMOM), is able to improve the lateral resolution by a factor of 2, reduce the background level, improve the optical sectioning effect and correct for unknown optical aberrations. In the acquisition process of VIKMOM, we used a scanning confocal microscope setup with a 2D detector array to capture sample information at each scanned x-y position. In the recovery process of VIKMOM, we first modulated the captured data by virtual k-space coding and then employed a ptychography-inspired procedure to recover the sample information and correct for unknown optical aberrations. We demonstrated the performance of the reported approach by imaging fluorescent beads, fixed bovine pulmonary artery endothelial (BPAE) cells, and living human astrocytes (HA). As the VIKMOM approach is fully compatible with conventional confocal microscope setups, it may provide a turn-key solution for imaging biological samples with ∼100  nm lateral resolution, in two or three dimensions, with improved optical sectioning capabilities and aberration correcting.

Indexed as

Microscopy, ConfocalOptics and PhotonicsAnimalsAstrocytesCattleEndothelial CellsHumansMicroscopy

Identifiers

PMID27447529
PMCPMC5548665

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.