Evidence map›Paper›PMID 27446711›Full record

ArticleBiomedical optics express2016

Imaging of targeted lipid microbubbles to detect cancer cells using third harmonic generation microscopy.

Kaitlin Harpel, Robert Dawson Baker, Babak Amirsolaimani, Soroush Mehravar, Josef Vagner, Terry O Matsunaga, Bhaskar Banerjee, Khanh Kieu

Open access · goldAbstract read
In one paragraph

Article in Biomedical optics express, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
2.4field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 32 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Review
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Kaitlin HarpelDepartment of Biomedical Engineering, University of Arizona, 1127 E. James E. Rogers Way, Tucson, Arizona, 85721, USA; Department of Medical Imaging, College of Medicine, University of Arizona, 1609 N. Warren Ave., Tucson, Arizona, 85719, USA.
Robert Dawson BakerCollege of Optical Sciences, University of Arizona, 1603 E. University Blvd., Tucson, AZ, 85721, USA.
Babak AmirsolaimaniCollege of Optical Sciences, University of Arizona, 1603 E. University Blvd., Tucson, AZ, 85721, USA.
Soroush MehravarCollege of Optical Sciences, University of Arizona, 1603 E. University Blvd., Tucson, AZ, 85721, USA.
Josef VagnerLigand Discovery Laboratory, BIO5 Institute, University of Arizona, 1657 E. Helen Street, Tucson, AZ, 85721, USA.
Terry O MatsunagaDepartment of Biomedical Engineering, University of Arizona, 1127 E. James E. Rogers Way, Tucson, Arizona, 85721, USA; Department of Medical Imaging, College of Medicine, University of Arizona, 1609 N. Warren Ave., Tucson, Arizona, 85719, USA.
Bhaskar BanerjeeDepartment of Biomedical Engineering, University of Arizona, 1127 E. James E. Rogers Way, Tucson, Arizona, 85721, USA; College of Optical Sciences, University of Arizona, 1603 E. University Blvd., Tucson, AZ, 85721, USA; Department of Medicine, College of Medicine, University of Arizona, 1501 N. Campbell, Tucson, Arizona, 85724, USA.
Khanh KieuCollege of Optical Sciences, University of Arizona, 1603 E. University Blvd., Tucson, AZ, 85721, USA.
University of Arizona · USRogers (United States) · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The use of receptor-targeted lipid microbubbles imaged by ultrasound is an innovative method of detecting and localizing disease. However, since ultrasound requires a medium between the transducer and the object being imaged, it is impractical to apply to an exposed surface in a surgical setting where sterile fields need be maintained and ultrasound gel may cause the bubbles to collapse. Multiphoton microscopy (MPM) is an emerging tool for accurate, label-free imaging of tissues and cells with high resolution and contrast. We have recently determined a novel application of MPM to be used for detecting targeted microbubble adherence to the upregulated plectin-receptor on pancreatic tumor cells. Specifically, the third-harmonic generation response can be used to detect bound microbubbles to various cell types presenting MPM as an alternative and useful imaging method. This is an interesting technique that can potentially be translated as a diagnostic tool for the early detection of cancer and inflammatory disorders.

Indexed as

(020.4180) Multiphoton processes(170.1610) Clinical applications(190.1900) Diagnostic applications of nonlinear optics(320.7090) Ultrafast lasers

Identifiers

PMID27446711
PMCPMC4948635
OpenAlexW2466976027

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.