Multiple pinhole collimator based X-ray luminescence computed tomography.

Wei Zhang, Dianwen Zhu, Michael Lun, Changqing Li

Abstract read
In one paragraph

Article in Biomedical optics express, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers.

0numbers the graph read from it
0cells of the map it votes in
19citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

19 citing papers in PubMed.

  1. Article
  2. Superfast Scan of Focused X-Ray Luminescence Computed Tomography Imaging.IEEE access : practical innovations, open solutions · 2023
    Article
  3. Article
  4. Article
  5. Article
  6. High-resolution x-ray luminescence computed tomography.Proceedings of SPIE--the International Society for Optical Engineering · 2020
    Article
  7. X-ray luminescence imaging for small animals.Proceedings of SPIE--the International Society for Optical Engineering · 2020
    Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Focused x-ray luminescence computed tomography: experimental studies.Proceedings of SPIE--the International Society for Optical Engineering · 2019
    Article
  13. Article
  14. Regularized reconstruction based on joint LBiomedical optics express · 2019
    Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Wei ZhangSchool of Engineering, University of California, Merced, Merced, CA 95343, USA.
Dianwen ZhuSchool of Engineering, University of California, Merced, Merced, CA 95343, USA.
Michael LunSchool of Engineering, University of California, Merced, Merced, CA 95343, USA.
Changqing LiSchool of Engineering, University of California, Merced, Merced, CA 95343, USA.

Funding

X-ray Luminescence Optical Tomography for Small Animal ImagingR21EB013828 · NIBIB · UNIVERSITY OF CALIFORNIA AT DAVIS · PI LI, CHANGQING · 2011 to 2012
$397k
Microscopic X-ray Luminescence Computed TomographyR03EB022305 · NIBIB · UNIVERSITY OF CALIFORNIA, MERCED · PI LI, CHANGQING · 2016 to 2017
$137k
NIBIB NIH HHS R03 EB022305NIBIB NIH HHS R21 EB013828
6 · The paper itself

Abstract

X-ray luminescence computed tomography (XLCT) is an emerging hybrid imaging modality, which is able to improve the spatial resolution of optical imaging to hundreds of micrometers for deep targets by using superfine X-ray pencil beams. However, due to the low X-ray photon utilization efficiency in a single pinhole collimator based XLCT, it takes a long time to acquire measurement data. Herein, we propose a multiple pinhole collimator based XLCT, in which multiple X-ray beams are generated to scan a sample at multiple positions simultaneously. Compared with the single pinhole based XLCT, the multiple X-ray beam scanning method requires much less measurement time. Numerical simulations and phantom experiments have been performed to demonstrate the feasibility of the multiple X-ray beam scanning method. In one numerical simulation, we used four X-ray beams to scan a cylindrical object with 6 deeply embedded targets. With measurements from 6 angular projections, all 6 targets have been reconstructed successfully. In the phantom experiment, we generated two X-ray pencil beams with a collimator manufactured in-house. Two capillary targets with 0.6 mm edge-to-edge distance embedded in a cylindrical phantom have been reconstructed successfully. With the two beam scanning, we reduced the data acquisition time by 50%. From the reconstructed XLCT images, we found that the Dice similarity of targets is 85.11% and the distance error between two targets is less than 3%. We have measured the radiation dose during XLCT scan and found that the radiation dose, 1.475 mSv, is in the range of a typical CT scan. We have measured the changes of the collimated X-ray beam size and intensity at different distances from the collimator. We have also studied the effects of beam size and intensity in the reconstruction of XLCT.

Indexed as

(170.3890) Medical optics instrumentation(170.6960) Tomography(170.7050) Turbid media(170.7440) X-ray imaging

Identifiers

PMID27446686
PMCPMC4948610

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.