Evidence map›Paper›PMID 27444834›Full record

ArticleSurgical endoscopy2017

Safety and effectiveness of self-adhesive mesh in laparoscopic ventral hernia repair using transabdominal preperitoneal route.

Juan Antonio Bellido Luque, Araceli Bellido Luque, Julio Gomez Menchero, Juan Manuel Suarez Grau, Joaquin García Moreno, Antonio Tejada Gomez, Juan Guadalajara Jurado

Erratum issuedAbstract read
PubMed Publisher
In one paragraph

Article in Surgical endoscopy, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.9field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 15 citations in OpenAlex.

  1. Trial
  2. Medial incisional ventral hernia repair with AdhesixHernia : the journal of hernias and abdominal wall surgery · 2023
    Article
  3. Article
  4. Article
  5. Article
  6. Robotic transabdominal preperitoneal approach for repair of primary, uncomplicated ventral hernias.Hernia : the journal of hernias and abdominal wall surgery · 2019
    Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Juan Antonio Bellido LuqueRiotinto Hospital, Minas de Riotinto, Huelva, Spain. j_bellido_l@hotmail.com.ORCID 0000-0002-6134-3782
Araceli Bellido LuqueQuirón Sagrado Corazón Hospital, Seville, Spain.
Julio Gomez MencheroRiotinto Hospital, Minas de Riotinto, Huelva, Spain.
Juan Manuel Suarez GrauRiotinto Hospital, Minas de Riotinto, Huelva, Spain.
Joaquin García MorenoRiotinto Hospital, Minas de Riotinto, Huelva, Spain.
Antonio Tejada GomezJuan Ramón Jimenez Hospital, Huelva, Spain.
Juan Guadalajara JuradoRiotinto Hospital, Minas de Riotinto, Huelva, Spain.
Hospital Riotinto · ESHospital Juan Ramón Jiménez · ESHospital Quirónsalud Sagrado Corazón · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundLaparoscopic ventral or incisional hernia repair requires intraperitoneal mesh placement. This is associated with an increase in adhesions, bowel obstruction and enterocutaneous fistula. Intraabdominal meshes are laparoscopically fixed using traumatic fixation methods that increase acute, chronic pain and adhesions to bowel loops. The aim was to check the safety and effectiveness of the laparoscopic approach in ventral or incisional hernia, using a self-adhesive mesh in the preperitoneal space without tacks or transfascial sutures, and to objectively assess its benefits and complications.

methodsPatients aged between 18 and 67 years old with medial, lateral ventral and incisional hernias between 3 and 8 cm in size were included in this study. Fifty patients were included in the study, which was conducted between January 2013 and March 2015.

resultsThe average length of surgery was 57.3 ± 18 min. The average hospital stay was 1.1 ± 0.3 days. The average time taken to return to work was 9.2 ± 2.4 days. The most common post-operative complication was seroma, which was observed in 13 patients (26 %). The average follow-up was 15.4 ± 5.5 months. Three patients were lost to follow-up during this period. There was no hernia recurrence during examination nor on CT scan during the follow-up period. The average score on the visual analogue scale before surgery was 4 ± 1. After surgery, the score was as follows: 3 ± 0.8 on the first day after surgery, 0.9 ± 0.5 after the first week, 0.4 ± 0.4 after the first month and 0 after 90 days. No patient showed chronic pain. Overall satisfaction (VAS for surgery) was 8.3 ± 0.6.

conclusionsThe use of self-adhesive meshes during the laparoscopic transabdominal preperitoneal approach in small- and medium-sized ventral or incisional hernias is safe and effective, with low post-operative pain, quick functional recovery and high overall satisfaction after surgery with no increase in recurrence in the short term.

Indexed as

AdhesivesLaparoscopySurgical MeshAdultAgedFemaleHernia, VentralHumansMaleMiddle AgedOperative TimePostoperative ComplicationsVisual Analog ScaleYoung AdultAdhesivesPreperitoneal herniaSelf-adhesive meshTransabdominal preperitoneal ventral hernia

Identifiers

PMID27444834
OpenAlexW2485261474

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked