Evidence map›Paper›PMID 27443916›Full record

ArticleJournal of medical ultrasonics (2001)2017

Improvement of penetration of modified amplitude and phase estimation beamformer.

Hideyuki Hasegawa

Abstract readEvaluation Study
PubMed Publisher
In one paragraph

Article in Journal of medical ultrasonics (2001), 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Apodized adaptive beamformer.Journal of medical ultrasonics (2001) · 2017
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Hideyuki HasegawaGraduate School of Science and Engineering, University of Toyama, Toyama, 930-8555, Japan. hasegawa@eng.u-toyama.ac.jp.ORCID http://orcid.org/0000-0003-0709-7821

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeHigh-frame-rate ultrasound is the predominant technique for the measurement of tissue dynamics. It enables an imaging frame rate of over 1 kHz using unfocused transmit beams and parallel receive beamforming. On the other hand, the spatial resolution is degraded compared to the conventional method based on sequential transmissions of focused beams. For improvement of the spatial resolution of high-frame-rate ultrasound, we have investigated a kind of adaptive beamformer, i.e., amplitude and phase estimation (APES) beamformer.

methodIn our previous study, it was shown that the APES beamformer realized a significantly better spatial resolution than the conventional delay and sum (DAS) beamformer without sub-array averaging and diagonal loading by considering the directivity of each transducer element. By omitting sub-array averaging and adding sub-aperture beamforming, the computational load could also be reduced significantly. One shortcoming of the proposed APES beamformer with element directivity, i.e., modified APES beamformer, is the degradation of penetration compared with the conventional APES beamformer with sub-array averaging and diagonal loading. In the present study, sub-array averaging and diagonal loading were applied to the modified APES beamformer for the improvement of the penetration.

resultsThe conventional and modified APES beamformers realized similar performances when used with sub-array averaging and diagonal loading. Furthermore, the modified APES beamformer realized better spatial resolution and improved penetration when used with sub-aperture beamforming and diagonal loading. The modified APES beamformer with diagonal loading at 0.025 of the received power realized a penetration similar to that of the conventional APES beamformer with sub-array averaging and diagonal loading. The lateral spatial resolutions achieved with the conventional and modified APES beamformers were 0.36 and 0.31 mm, respectively. In addition, the modified APES beamformer could reduce the dimension of the covariance matrix to [Formula: see text], versus [Formula: see text] of the conventional APES beamformer, resulting in a computation time of only 1.1 %.

conclusionPenetration of the modified APES beamformer could be improved significantly by diagonal loading, which hardly increases the computational complexity.

Indexed as

AlgorithmsImage Processing, Computer-AssistedPhantoms, ImagingUltrasonic WavesUltrasonographyAdaptive beamformingHigh-frame-rate ultrasoundPenetrationSpatial resolution

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.