Evidence map›Paper›PMID 27443328›Full record

ArticleInternational journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group2016

MRI-guided focused ultrasound ablation of lumbar medial branch nerve: Feasibility and safety study in a swine model.

Elena A Kaye, Sebastien Monette, Govindarajan Srimathveeravalli, Majid Maybody, Stephen B Solomon, Amitabh Gulati

Registry-linked trialOpen access · bronzeAbstract read
In one paragraph

Article in International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03168802 (Comparative Study of Magnetic Resonance-guided Focused Ultrasound and Radiofrequency Ablation for Treatment of Facet-joint Osteoarthritis Low Back Pain), which is not on this map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
1.0field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT03168802 narecruitingnot on this mapstarted 2018, after this paper: background citation

Comparative Study of Magnetic Resonance-guided Focused Ultrasound and Radiofrequency Ablation for Treatment of Facet-joint Osteoarthritis Low Back Pain

TypeinterventionalSponsorTaipei Medical University HospitalRan2018 to 2025Enrolled100ConditionsChronic Low Back Pain, Facet Joint SyndromeArmsMRgFUS ablation, Radiofrequency ablation
3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 25 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Review
  6. Review
  7. Review
  8. Article
  9. Article
  10. Article
  11. Review
  12. Review
  13. Article
  14. Review
  15. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Elena A Kayea Department of Medical Physics , Memorial Sloan Kettering Cancer Center , New York ;
Sebastien Monetteb Tri-Institutional Laboratory of Comparative Pathology, Memorial Sloan Kettering Cancer Center , Rockefeller University, Weill Cornell Medical College , New York ;
Govindarajan Srimathveeravallic Department of Radiology , Memorial Sloan Kettering Cancer Center , New York ;
Majid Maybodyc Department of Radiology , Memorial Sloan Kettering Cancer Center , New York ;
Stephen B Solomonc Department of Radiology , Memorial Sloan Kettering Cancer Center , New York ;
Amitabh Gulatid Department of Anesthesiology , Memorial Sloan Kettering Cancer Center , New York , USA.
Memorial Sloan Kettering Cancer Center · US

Funding

X-RAY CRYSTALLOGRAPHYP30CA008748 · NCI · SLOAN-KETTERING INSTITUTE FOR CANCER RES · PI Elisa de Stanchina · 1985 to 2026
$347.4M
NCI NIH HHS P30 CA008748
6 · The paper itself

Abstract

purposeAbout 10-40% of chronic low back pain cases involve facet joints, which are commonly treated with lumbar medial branch (MB) radiofrequency neurotomy. Magnetic resonance imaging-guided focused ultrasound (MRgFUS), a non-invasive, non-ionising ablation modality used to treat tumours, neuropathic pain and painful bone metastasis can also be used to disrupt nerve conduction. This work's purpose was to study the feasibility and safety of direct MRgFUS ablation of the lumbar MB nerve in acute and subacute swine models. MATERIALS AND

methodsIn vivo MRgFUS ablation was performed in six swine (three acute and three subacute) using a clinical MRgFUS system and a 3-T MRI scanner combination. Behavioural assessment was performed, and imaging and histology were used to assess the treatment. RESULTS AND

conclusionsHistological analysis of the in vivo studies confirmed thermal necrosis of the MB nerve could be achieved without damaging the spinal cord or adjacent nerve roots. MRgFUS did not cause changes in the animals' behaviour or ambulation.

Indexed as

AnimalsCattleDisease Models, AnimalFeasibility StudiesFemaleHigh-Intensity Focused Ultrasound AblationHumansMagnetic Resonance ImagingNerve BlockFacet jointFUSHIFUMRI-guidednerve ablationswine model

Identifiers

PMID27443328
PMCPMC5206657
OpenAlexW2501785100

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.