ArticleJournal of controlled release : official journal of the Controlled Release Society2016
Drug deposition in coronary arteries with overlapping drug-eluting stents.
Article in Journal of controlled release : official journal of the Controlled Release Society, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed.
- Minimally overlapping technique of bioresorbable scaffolds in a porcine coronary artery model: proof-of-concept study.Scientific reports · 2025Article
- Morphology-Based Non-Rigid Registration of Coronary Computed Tomography and Intravascular Images Through Virtual Catheter Path Optimization.IEEE transactions on medical imaging · 2025Article
- Computational modeling of drug-eluting balloons in peripheral artery disease: Mechanisms, optimization, and translational insights.Computational and structural biotechnology journal · 2025Review
- A Strategy for the In-Silico Assessment of Drug Eluting Stents: A Comparative Study for the Evaluation of Retinoic Acid as a Novel Drug Candidate for Drug Eluting Stents.IEEE open journal of engineering in medicine and biology · 2025Article
- Cardiovascular Tissue Engineering Models for Atherosclerosis Treatment Development.Bioengineering (Basel, Switzerland) · 2023Review
- Review
- Regulatory perspectives of combination products.Bioactive materials · 2022Review
- One-year outcomes of novel BioMime Morph tapered stent in long and multiple coronary artery lesions.Anatolian journal of cardiology · 2021Article
- Evolution of drug-eluting biomedical implants for sustained drug delivery.European journal of pharmaceutics and biopharmaceutics : official journal of Arbeitsgemeinschaft fur Pharmazeutische Verfahrenstechnik e.V · 2021Review
- Acute Stent-Induced Endothelial Denudation: Biomechanical Predictors of Vascular Injury.Frontiers in cardiovascular medicine · 2021Article
- 3D modelling of drug-coated balloons for the treatment of calcified superficial femoral arteries.PloS one · 2021Article
- Position Paper Computational Cardiology.IEEE journal of biomedical and health informatics · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
Drug-eluting stents are accepted as mainstream endovascular therapy, yet concerns for their safety may be under-appreciated. While failure from restenosis has dropped to below 5%, the risk of stent thrombosis and associated mortality remain relatively high. Further optimization of drug release is required to minimize thrombosis risk while maintaining therapeutic dose. The complex three-dimensional geometry of deployed stents together with the combination of diffusive and advective drug transport render an intuitive understanding of the situation exceedingly difficult. In situations such as this, computational modeling has proven essential, helping define the limits of efficacy, determine the mode and mechanism of drug release, and identify alternatives to avoid toxicity. A particularly challenging conformation is encountered in coronary arteries with overlapping stents. To study hemodynamics and drug deposition in such vessels we combined high-resolution, multi-scale ex vivo computed tomography with a flow and mass transfer computational model. This approach ensures high geometric fidelity and precise, simultaneous calculation of blood flow velocity, shear stress and drug distribution. Our calculations show that drug uptake by the arterial tissue is dependent both on the patterns of flow disruption near the wall, as well as on the relative positioning of drug-eluting struts. Overlapping stent struts lead to localized peaks of drug concentration that may increase the risk of thrombosis. Such peaks could be avoided by anisotropic stent structure or asymmetric drug release designed to yield homogeneous drug distribution along the coronary artery and, at the least, suggest that these issues need to remain in the forefront of consideration in clinical practice.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.