SynthesisClinical orthopaedics and related research2016
The Biologic Response to Polyetheretherketone (PEEK) Wear Particles in Total Joint Replacement: A Systematic Review.
Synthesis in Clinical orthopaedics and related research, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 35 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
35 citing papers in PubMed, 99 citations in OpenAlex.
- Consequences of using poly-ether-ether-ketone versus traditional implant on tibial cement penetration and short-term clinical outcomes during total knee arthroplasty: a randomized controlled trial.Journal of orthopaedic surgery and research · 2023Trial
- Soft, Reactive, and Alive: A Dynamic Framework for Degradation and Functional Stability of Polymeric Biomaterials.Polymers · 2026Review
- The Influence of Mechanical and Microstructural Characteristics on the Durability of a Femoral Implant Made of Different Alloys.Journal of functional biomaterials · 2026Article
- Network Toxicology and Molecular Docking Analysis of Targets and Potential Mechanisms of PEEK-Induced Bone Resorption.International journal of molecular sciences · 2026Article
- Biocompatibility, Durability, and Stability Assessment of an Unconstrained Metacarpophalangeal Joint Prosthesis With Zirconia (ZrOJournal of hand surgery global online · 2026Article
- Enhanced crystallinity, hardness and thermal stability of PEEK/TC4 composites for biomedical applications.Scientific reports · 2026Article
- Role of polyetheretherketone (PEEK) in arthroplasty and orthopaedics: a review of biomechanical properties, surface modifications, and clinical outcomes.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2026Review
- Clinical Evidence of Wear Occurrence in CFR-PEEK and Metallic Osteosynthesis Implants: A Systematic Literature Review.Bioengineering (Basel, Switzerland) · 2025Review
- Application of biodegradable implants in pediatric orthopedics: shifting from absorbable polymers to biodegradable metals.Bioactive materials · 2025Article
- Spinal implant wear particles: Generation, characterization, biological impacts, and future considerations.iScience · 2025Review
- Biomechanical Comparison of a Novel PEEK Tibial Cortical Suspension Device With 6 Metallic Femoral Cortical Suspension Devices Used in Anterior Cruciate Ligament Reconstruction.Orthopaedic journal of sports medicine · 2025Article
- Poly-ether-ether-ketone wear particles induce a pro-inflammatory phenotype in a human monocytic cell line.Frontiers in bioengineering and biotechnology · 2025Article
- Use of Biomaterials in 3D Printing as a Solution to Microbial Infections in Arthroplasty and Osseous Reconstruction.Biomimetics (Basel, Switzerland) · 2024Review
- Absorbable implants in sport medicine and arthroscopic surgery: A narrative review of recent development.Bioactive materials · 2024Review
- A self-assembling graphene oxide coating for enhanced bactericidal and osteogenic properties of poly-ether-ether-ketone.Frontiers in bioengineering and biotechnology · 2024Article
- Antibacterial properties of antimicrobial peptide HHC36 modified polyetheretherketone.Frontiers in microbiology · 2023Article
- Strategies to improve bioactive and antibacterial properties of polyetheretherketone (PEEK) for use as orthopedic implants.Materials today. Bio · 2022Review
- Review
- Comparison of Titanium and PEEK Medical Plastic Implant Materials for Their Bacterial Biofilm Formation Properties.Polymers · 2022Article
- Experimental testing of fracture fixation plates: A review.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2022Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundPolyetheretherketone (PEEK) and its composites are polymers resistant to fatigue strain, radiologically transparent, and have mechanical properties suitable for a range of orthopaedic applications. In bulk form, PEEK composites are generally accepted as biocompatible. In particulate form, however, the biologic response relevant to joint replacement devices remains unclear. The biologic response to wear particles affects the longevity of total joint arthroplasties. Particles in the phagocytozable size range of 0.1 µm to 10 µm are considered the most biologically reactive, particularly particles with a mean size of < 1 µm. This systematic review aimed to identify the current evidence for the biologic response to PEEK-based wear debris from total joint arthroplasties. QUESTIONS/PURPOSES: (1) What are the quantitative characteristics of PEEK-based wear particles produced by total joint arthroplasties? (2) Do PEEK wear particles cause an adverse biologic response when compared with UHMWPE or a similar negative control biomaterial? (3) Is the biologic response affected by particle characteristics?
methodsEmbase and Ovid Medline databases were searched for studies that quantified PEEK-based particle characteristics and/or investigated the biologic response to PEEK-based particles relevant to total joint arthroplasties. The keyword search included brands of PEEK (eg, MITCH, MOTIS) or variations of PEEK types and nomenclature (eg, PAEK, CFR-PEEK) in combination with types of joint (eg, hip, knee) and synonyms for wear debris or immunologic response (eg, particles, cytotoxicity). Peer-reviewed studies, published in English, investigating total joint arthroplasty devices and cytotoxic effects of PEEK particulates were included. Studies investigating devices without articulating bearings (eg, spinal instrumentation devices) and bulk material or contact cytotoxicity were excluded. Of 129 studies, 15 were selected for analysis and interpretation. No studies were found that isolated and characterized PEEK wear particles from retrieved periprosthetic human tissue samples.
resultsIn the four studies that quantified PEEK-based particles produced using hip, knee, and spinal joint replacement simulators, the mean particle size was 0.23 µm to 2.0 µm. The absolute range reported was approximately 0.01 µm to 50 µm. Rod-like carbon particulates and granular-shaped PEEK particles were identified in human tissue by histologic analysis. Ten studies, including six animal models (rat, mouse, and rabbit), three cell line experiments, and two human tissue retreival studies, investigated the biologic response to PEEK-based particles. Qualitative histologic assessments showed immunologic cell infiltration to be similar for PEEK particles when compared with UHMWPE particles in all six of the animal studies identified. However, increased inflammatory cytokine release (such as tumor necrosis factor-α) was identified in only one in vitro study, but without substantial suppression in macrophage viability. Only one study tested the effects of particle size on cytotoxicity and found the largest unfilled PEEK particles (approximately 13 µm) to have a toxic effect; UHMWPE particles in the same size range showed a similar cytotoxic effect.
conclusionsWear particles produced by PEEK-based bearings were, in almost all cases, in the phagocytozable size range (0.1-10 µm). The studies that evaluated the biologic response to PEEK-based particles generally found cytotoxicity to be within acceptable limits relative to the UHMWPE control, but inconsistent when inflammatory cytokine release was considered. CLINICAL RELEVANCE: To translate new and advanced materials into clinical use more quickly, the clinical relevance and validity of preclinical tests need to be improved. To achieve this for PEEK-based devices, human tissue retrieval studies including subsequent particle isolation and characterization analyses are required. In vitro cell studies using isolated wear particles from tissue or validated joint replacement simulators, instead of manufactured particles, are also required.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.