Evidence map›Paper›PMID 27430972›Full record

ArticleBMC oral health2016

Influence of light-curing distance on degree of conversion and cytotoxicity of etch-and-rinse and self-etch adhesives.

Florian J Wegehaupt, Nancy Lunghi, Georgios N Belibasakis, Thomas Attin

Open access · goldAbstract read
In one paragraph

Article in BMC oral health, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
2.3field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 38 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Review
  5. Effects of AdperMaterials (Basel, Switzerland) · 2021
    Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. BioMed research international · 2019
    Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Florian J WegehauptClinic for Preventive Dentistry, Periodontology and Cariology, University of Zurich, Plattenstrasse 11, 8032, Zürich, Switzerland. florian.wegehaupt@zzm.uzh.ch.ORCID http://orcid.org/0000-0002-3972-0561
Nancy LunghiClinic for Preventive Dentistry, Periodontology and Cariology, University of Zurich, Plattenstrasse 11, 8032, Zürich, Switzerland.
Georgios N BelibasakisSection of Oral Microbiology and Immunology, Institute of Oral Biology, University of Zürich, Plattenstrasse 11, 8032, Zürich, Switzerland.
Thomas AttinClinic for Preventive Dentistry, Periodontology and Cariology, University of Zurich, Plattenstrasse 11, 8032, Zürich, Switzerland.
University of Zurich · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe degree of conversion (DC) of resin based materials depends, beside other factors, on the light-intensity applied during light curing. A lower DC might be correlated with an increased cytotoxicity of the respective materials. Therefore, aim of the present study was to investigate the influence of the distance between light-curing tip and adhesives on their cytotoxicity and degree of conversion (DC).

methodsFor the cytotoxicity assay, a total of 98 bovine dentine samples were prepared, distributed to seven groups (G1-G7; n = 14) and treated as follows: G1: untreated; G2-G4: OptiBond FL; G5-G7: OptiBond All-In-One. Adhesives were light-cured (1200 mW/cm(2)) at 1 mm (G2;G5), 4 mm (G3;G6) or 7 mm (G4;G7) distance. Samples were stored in culture media for 24 h and extracts were added to cell cultures (dental pulp cells and gingival fibroblasts) for a further 24 h. Finally, released lactate dehydrogenase activity (LDH) was photometrically determined, as measure for the cytotoxic effects of the extracts. The cytotoxicity assay was performed three times. Additionally, the DC of the adhesives was determined by FTIR spectroscopy. DC measurements were performed five times.

resultsFor both cell types, no significant difference of LDH release was observed between untreated control group (G1) and treated groups G2-G7 (p > 0.05, respectively), between the groups treated with same adhesive and light-cured at different distance (p > 0.05, respectively), as well as between groups treated with different adhesives and light-cured at the same distance (p > 0.05, respectively). Within the respective adhesive, no significant difference in the DC was observed when light-cured at different distance (p > 0.05, respectively), while OptiBond FL showed significantly higher DCs compared to OptiBond All-In-One when light-cured at same distances (p < 0.05, respectively).

conclusionsThe distance between light-curing tip and adhesive surface does not significantly influence either the cytotoxicity or the DC of the tested adhesives.

Indexed as

Curing Lights, DentalDental CementsAnimalsCattleComposite ResinsLight-Curing of Dental AdhesivesMaterials TestingResin CementsSpectroscopy, Fourier Transform InfraredComposite ResinsDental CementsResin CementsCytotoxicityDegree of conversionDental adhesivesLight-curing

Identifiers

PMID27430972
PMCPMC4948104
OpenAlexW2480039327

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked