Evidence map›Paper›PMID 27429997›Full record

ArticleJournal of medical imaging (Bellingham, Wash.)2016

Three-dimensional registration of intravascular optical coherence tomography and cryo-image volumes for microscopic-resolution validation.

David Prabhu, Emile Mehanna, Madhusudhana Gargesha, Eric Brandt, Di Wen, Nienke S van Ditzhuijzen, Daniel Chamie, Hirosada Yamamoto, Yusuke Fujino, Ali Alian and 4 more

Abstract read
In one paragraph

Article in Journal of medical imaging (Bellingham, Wash.), 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

David PrabhuCase Western Reserve University , Department of Biomedical Engineering, Cleveland, 10900 Euclid Ave, Cleveland, Ohio 44106, United States.
Emile MehannaUniversity Hospitals Case Medical Center , Harrington Heart and Vascular Institute, Cardiovascular Imaging Core Laboratory, 11100 Euclid Avenue, Cleveland, Ohio 44106, United States.
Madhusudhana GargeshaCase Western Reserve University , Department of Biomedical Engineering, Cleveland, 10900 Euclid Ave, Cleveland, Ohio 44106, United States.
Eric BrandtUniversity Hospitals Case Medical Center , Harrington Heart and Vascular Institute, Cardiovascular Imaging Core Laboratory, 11100 Euclid Avenue, Cleveland, Ohio 44106, United States.
Di WenUniversity Hospitals Case Medical Center, Harrington Heart and Vascular Institute, Cardiovascular Imaging Core Laboratory, 11100 Euclid Avenue, Cleveland, Ohio 44106, United States; Case Western Reserve University, Department of Biomedical Engineering, Cleveland, 10900 Euclid Ave, Cleveland, Ohio 44106, United States.
Nienke S van DitzhuijzenUniversity Hospitals Case Medical Center , Harrington Heart and Vascular Institute, Cardiovascular Imaging Core Laboratory, 11100 Euclid Avenue, Cleveland, Ohio 44106, United States.
Daniel ChamieUniversity Hospitals Case Medical Center , Harrington Heart and Vascular Institute, Cardiovascular Imaging Core Laboratory, 11100 Euclid Avenue, Cleveland, Ohio 44106, United States.
Hirosada YamamotoUniversity Hospitals Case Medical Center , Harrington Heart and Vascular Institute, Cardiovascular Imaging Core Laboratory, 11100 Euclid Avenue, Cleveland, Ohio 44106, United States.
Yusuke FujinoUniversity Hospitals Case Medical Center , Harrington Heart and Vascular Institute, Cardiovascular Imaging Core Laboratory, 11100 Euclid Avenue, Cleveland, Ohio 44106, United States.
Ali AlianUniversity Hospitals Case Medical Center , Harrington Heart and Vascular Institute, Cardiovascular Imaging Core Laboratory, 11100 Euclid Avenue, Cleveland, Ohio 44106, United States.
Jaymin PatelCase Western Reserve University , Department of Biomedical Engineering, Cleveland, 10900 Euclid Ave, Cleveland, Ohio 44106, United States.
Marco CostaUniversity Hospitals Case Medical Center , Harrington Heart and Vascular Institute, Cardiovascular Imaging Core Laboratory, 11100 Euclid Avenue, Cleveland, Ohio 44106, United States.
Hiram G BezerraUniversity Hospitals Case Medical Center , Harrington Heart and Vascular Institute, Cardiovascular Imaging Core Laboratory, 11100 Euclid Avenue, Cleveland, Ohio 44106, United States.
David L WilsonCase Western Reserve University , Department of Biomedical Engineering, Cleveland, 10900 Euclid Ave, Cleveland, Ohio 44106, United States.

Funding

In vivo Characterization of Stents using Intravascular OCT ImagingR01HL114406 · NHLBI · CASE WESTERN RESERVE UNIVERSITY · PI BEZERRA, HIRAM, ROLLINS, ANDREW MARTIN · 2013 to 2016
$1.7M
Coronary Plaque Characterization with Vascular OCT ImagingR21HL108263 · NHLBI · CASE WESTERN RESERVE UNIVERSITY · PI COSTA, MARCO A, WILSON, DAVID LYNN · 2011 to 2012
$423k
NHLBI NIH HHS R01 HL114406NHLBI NIH HHS R21 HL108263
6 · The paper itself

Abstract

Evidence suggests high-resolution, high-contrast, [Formula: see text] intravascular optical coherence tomography (IVOCT) can distinguish plaque types, but further validation is needed, especially for automated plaque characterization. We developed experimental and three-dimensional (3-D) registration methods to provide validation of IVOCT pullback volumes using microscopic, color, and fluorescent cryo-image volumes with optional registered cryo-histology. A specialized registration method matched IVOCT pullback images acquired in the catheter reference frame to a true 3-D cryo-image volume. Briefly, an 11-parameter registration model including a polynomial virtual catheter was initialized within the cryo-image volume, and perpendicular images were extracted, mimicking IVOCT image acquisition. Virtual catheter parameters were optimized to maximize cryo and IVOCT lumen overlap. Multiple assessments suggested that the registration error was better than the [Formula: see text] spacing between IVOCT image frames. Tests on a digital synthetic phantom gave a registration error of only [Formula: see text] (signed distance). Visual assessment of randomly presented nearby frames suggested registration accuracy within 1 IVOCT frame interval ([Formula: see text]). This would eliminate potential misinterpretations confronted by the typical histological approaches to validation, with estimated 1-mm errors. The method can be used to create annotated datasets and automated plaque classification methods and can be extended to other intravascular imaging modalities.

Indexed as

cryo-imaginghistologyintravascular imagingoptical coherence tomographythree-dimensional image registrationvalidation

Identifiers

PMID27429997
PMCPMC4923671

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.