ArticleSpringerPlus2016
Rapid sample processing for intracellular metabolite studies in Penicillium ochrochloron CBS 123.824: the FiltRes-device combines cold filtration of methanol quenched biomass with resuspension in extraction solution.
Article in SpringerPlus, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 3 citations in OpenAlex.
- Molecular responses during bacterial filamentation reveal inhibition methods of drug-resistant bacteria.Proceedings of the National Academy of Sciences of the United States of America · 2023Article
- Critical evaluation of a putative glucosamine excretion by Aspergillus niger CBS120.49 and Penicillium ochrochloron CBS123.824 under citric acid producing conditions.Scientific reports · 2019Article
- The Dynamics of Plasma Membrane, Metabolism and Respiration (PM-M-R) inFrontiers in microbiology · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
Abstract
backgroundMany issues concerning sample processing for intracellular metabolite studies in filamentous fungi still need to be solved, e.g. how to reduce the contact time of the biomass to the quenching solution in order to minimize metabolite leakage. Since the required time to separate the biomass from the quenching solution determines the contact time, speeding up this step is thus of utmost interest. Recently, separation approaches based on cold-filtration were introduced as promising alternative to cold-centrifugation, which exhibit considerably reduced contact times. In previous works we were unable to obtain a compact pellet from cold methanol quenched samples of the filamentous fungus Penicillium ochrochloron CBS 123.824 via centrifugation. Therefore our aim was to establish for this organism a separation technique based on cold-filtration to determine intracellular levels of a selected set of nucleotides.
resultsWe developed a cold-filtration based technique as part of our effort to revise the entire sample processing method and analytical procedure. The Filtration-Resuspension (FiltRes) device combined in a single apparatus (1) a rapid cold-filtration and (2) a rapid resuspension of the biomass in hot extraction solution. Unique to this is the injection of the extraction solution from below the membrane filter (FiltRes-principle). This caused the mycelial cake to detach completely from the filter membrane and to float upwards so that the biomass could easily be transferred into preheated tubes for metabolite extraction. The total contact time of glucose-limited chemostat mycelium to the quenching solution could be reduced to 15.7 ± 2.5 s, whereby each washing step added another 10-15 s. We evaluated critical steps like filtration time, temperature profile, reproducibility of results, and using the energy charge (EC) as a criterion, effectiveness of enzyme destruction during the transition in sample temperature from cold to hot. As control we used total broth samples quenched in hot ethanol. Averaged over all samples an EC of 0.93 ± 0.020 was determined with the FiltRes-principle compared to 0.89 ± 0.049 with heat stopped total broth samples.
conclusionsWe concluded that for P. ochrochloron this technique is a reliable sample processing method for intracellular metabolite analysis, which might offer also other possible applications.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.