Trial reportInvestigative ophthalmology & visual science2016
Impact of Microscope-Integrated OCT on Ophthalmology Resident Performance of Anterior Segment Surgical Maneuvers in Model Eyes.
Trial report in Investigative ophthalmology & visual science, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT01588041 (Intraoperative OCT Guidance of Intraocular Surgery), which is not on this map. Cited by 24 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Intraoperative OCT Guidance of Intraocular Surgery
Who cites it
24 citing papers in PubMed, 1 synthesis or guideline pooled it, 35 citations in OpenAlex.
- A systematic review of simulation-based training tools for technical and non-technical skills in ophthalmology.Eye (London, England) · 2020Pooled it
- Remote corneal suturing wet lab: microsurgical education during the COVID-19 pandemic.Journal of cataract and refractive surgery · 2020Trial
- Microscope-integrated Intraoperative Optical Coherence Tomography for Anterior Segment Surgical Maneuvers.Translational vision science & technology · 2020Trial
- [Intraoperative OCT (iOCT)/microscope-integrated OCT (MI-OCT) in anterior segment diagnostics and surgical treatment].Die Ophthalmologie · 2026Review
- The Feasibility and Clinical Evaluation of an Immersive Augmented Reality Surgical Headset Integrated with Swept-Source Intraoperative Optical Coherence Tomography for Ophthalmic Surgery in the DISCOVER Study.Diagnostics (Basel, Switzerland) · 2025Article
- Methods for real-time feature-guided image fusion of intrasurgical volumetric optical coherence tomography with digital microscopy.Biomedical optics express · 2023Article
- Quantitative measurements of intraocular structures and microinjection bleb volumes using intraoperative optical coherence tomography.Biomedical optics express · 2023Article
- Automated instrument-tracking for 4D video-rate imaging of ophthalmic surgical maneuvers.Biomedical optics express · 2022Article
- Resident Skills Assessment in Corneal Suturing: A Comprehensive Review of Currently Proposed Educational Programs and Evaluation Tools.Journal of academic ophthalmology (2017) · 2021Article
- A Review of Robotic and OCT-Aided Systems for Vitreoretinal Surgery.Advances in therapy · 2021Review
- Comprehensive review of surgical microscopes: technology development and medical applications.Journal of biomedical optics · 2021Review
- Optical Coherence Tomography Guided Robotic Needle Insertion for Deep Anterior Lamellar Keratoplasty.IEEE transactions on bio-medical engineering · 2020Article
- What Is the Impact of Intraoperative Microscope-Integrated OCT in Ophthalmic Surgery? Relevant Applications and Outcomes. A Systematic Review.Journal of clinical medicine · 2020Review
- Intraoperative Optical Coherence Tomography Guided Ocular Surgeries: Critical Analysis of Clinical Role and Future Perspectives.Clinical ophthalmology (Auckland, N.Z.) · 2020Review
- Article
- Constant linear velocity spiral scanning for near video rate 4D OCT ophthalmic and surgical imaging with isotropic transverse sampling.Biomedical optics express · 2018Article
- THE INTEGRATIVE SURGICAL THEATER: Combining Intraoperative Optical Coherence Tomography and 3D Digital Visualization for Vitreoretinal Surgery in the DISCOVER Study.Retina (Philadelphia, Pa.) · 2018Article
- Real-time visualization and interaction with static and live optical coherence tomography volumes in immersive virtual reality.Biomedical optics express · 2018Article
- Review of intraoperative optical coherence tomography: technology and applications [Invited].Biomedical optics express · 2017Article
- Area and volume ratios for prediction of visual outcome in idiopathic macular hole.International journal of ophthalmology · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors at 1 institution in 1 country.
Funding
Abstract
purposeThe integration of swept-source optical coherence tomography (SS-OCT) into the operating microscope enables real-time, tissue-level three-dimensional (3D) imaging to aid in ophthalmic microsurgery. In this prospective randomized controlled study, we evaluated the impact of SS microscope-integrated OCT (MI-OCT) on ophthalmology residents' performance of ophthalmic microsurgical maneuvers.
methodsFourteen ophthalmology residents from a single institution were stratified by year of training and randomized to perform four anterior segment surgical maneuvers on porcine eyes with (MI-OCT+) or without (MI-OCT-) direct intraoperative OCT guidance. Subsequently, both groups repeated the same maneuvers without MI-OCT feedback to test whether initial MI-OCT experience affected subsequent surgical performance. Finally, the MI-OCT- group was crossed over and allowed to repeat the same maneuvers with direct MI-OCT guidance. Each resident completed a survey at the completion of the study.
resultsWith direct MI-OCT feedback, residents demonstrated enhanced performance in depth-based anterior segment maneuvers (corneal suture passes at 50% and 90% depth and corneal laceration repair) compared with the residents operating without MI-OCT. Microscope-integrated OCT+ residents continued to outperform the controls when both groups subsequently operated without MI-OCT. For clear corneal wound geometry, there was no statistically significant effect of MI-OCT as applied in this study. Overall, the resident surgeons rated their subjective experience of using MI-OCT very favorably.
conclusionsMicroscope-integrated OCT feedback enhances performance of ophthalmology residents in select anterior segment surgical maneuvers. Microscope-integrated OCT represents a valuable tool in the surgical education of ophthalmology residents.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.