Evidence map›Paper›PMID 27408867›Full record

ArticleAsia Oceania journal of nuclear medicine & biology2014

Performance of Myocardial Perfusion Imaging Using Multi-focus Fan Beam Collimator with Resolution Recovery Reconstruction in a Comparison with Conventional SPECT.

Norikazu Matsutomo, Akio Nagaki, Masayuki Sasaki

Open access · greenAbstract read
In one paragraph

Article in Asia Oceania journal of nuclear medicine & biology, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.9field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Effect of reduced photon count levels and choice of normal data on semi-automated image assessment in cardiac SPECT.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2020
    Article
  5. Creation and characterization of normal myocardial perfusion imaging databases using the IQ·SPECT system.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2018
    Article
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Norikazu MatsutomoDepartment of Radiology, Kurashiki Central Hospital, Kurashiki, Japan; Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan.
Akio NagakiDepartment of Radiology, Kurashiki Central Hospital, Kurashiki, Japan.
Masayuki SasakiDepartment of Health Sciences, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan.
Kurashiki Central Hospital · JPKyushu University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesIQ-SPECT is an advanced high-speed SPECT modality for myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQ-SPECT with conventional SPECT in terms of performance, based on standard clinical protocols. In addition, we examined the concordance between conventional and IQ_SPECT in patients with coronary artery disease (CAD).

methodsFifty-three patients, undergoing rest-gated MPI for the evaluation of known or suspected CAD, were enrolled in this study. In each patient, conventional SPECT ((99m)Tc-tetrofosmin, 9.6 min and (201)Tl, 12.9 min) was performed, immediately followed by IQ-SPECT, using a short acquisition time (4.3 min for (99m)Tc-tetrofosmin and 6.2 min for (201)Tl). A quantitative analysis was performed on an MPI polar map, using a 20-segment model of the left ventricle. An automated analysis by gated SPECT was carried out to determine the left ventricular volume and function including end-diastolic volume (EDV), end-systolic volume (ESV), and left ventricular ejection fraction (LVEF). The degree of concordance between conventional SPECT and IQ-SPECT images was evaluated according to linear regression and Bland-Altman analyses.

resultsThe segmental percent uptake exhibited a significant correlation between IQ-SPECT and conventional SPECT (P<0.05). The mean differences in (99m)Tc-tetrofosmin studies were 1.1±6.6% (apex), 2.8±5.7% (anterior wall), 2.9±6.2% (septal wall), 4.9±6.7% (lateral wall), and 1.8±5.6% (inferior wall). Meanwhile, regarding the (201)Tl-SPECT studies, these values were 1.6±6.9%, 2.0±6.6%, 2.1±5.9%, 3.3±7.2%, and 2.4±5.8%, respectively. Although the mean LVEF in IQ-SPECT tended to be higher than that observed in conventional SPECT (conventional SPECT=64.8±11.8% and IQ-SPECT=68.3±12.1% for (99m)Tc-tetrofosmin; conventional SPECT= 56.0±11.7% and IQ-SPECT=61.5±12.2% for (201)Tl), quantitative parameters were not significantly different between IQ-SPECT and conventional SPECT.

conclusionAccording to the (99m)Tc-tetrofosmin and (201)Tl protocols, IQ-SPECT images were comparable to and in agreement with conventional SPECT images. Our results suggest that IQ-SPECT is a useful technology for MPI SPECT, and can lead to an increase in scan efficiency and patient comfort.

Indexed as

Comparable imagesMulti-focus fan beam collimatorMyocardial perfusion imagingResolution recovery reconstru-ction

Identifiers

PMID27408867
PMCPMC4937695
OpenAlexW1887172499

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.