ArticleEuropean spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society2016
A pedicle screw system and a lamina hook system provide similar primary and long-term stability: a biomechanical in vitro study with quasi-static and dynamic loading conditions.
Article in European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 23 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
23 citing papers in PubMed, 42 citations in OpenAlex.
- Radiological evaluation and complications of percutaneous vertebroplasty and fenestrated pedicle screw fixation with bone cement augmentation: propensity-score matched cohort study.BMC musculoskeletal disorders · 2026Article
- Indications of Clinical Application of L5 Laminar Hook for the Surgical Correction of Degenerative Sagittal Imbalance.Medicina (Kaunas, Lithuania) · 2025Article
- Prediction of screw loosening by measuring the insertion torque in non-osteoporotic patients: an in vitro study.BMC musculoskeletal disorders · 2025Article
- Predictive factors of distal pedicle screw loosening followed posterior corrective surgery for degenerative lumbar scoliosis.BMC musculoskeletal disorders · 2025Article
- Main elements of current spine biomechanics research: model, installation and test data.Frontiers in bioengineering and biotechnology · 2025Review
- Surgical treatment of scoliosis in patients with osteogenesis imperfecta: a single institution case series.Musculoskeletal surgery · 2024Article
- Advancing the design of interspinous fixation devices for improved biomechanical performance: dualJournal of spine surgery (Hong Kong) · 2024Article
- Validation of a patient-specific finite element analysis framework for identification of growing rod-failure regions in early onset scoliosis patients.Spine deformity · 2024Article
- A novel approach to surgical treatment of adolescent idiopathic scoliosis in skeletally immature patients.World neurosurgery: X · 2024Article
- Comparison of four in vitro test methods to assess nucleus pulposus replacement device expulsion risk.JOR spine · 2024Article
- The Biomechanical Properties of Cement-Augmented Pedicle Screws for Osteoporotic Spines.Global spine journal · 2022Article
- Three-Dimensional Biomechanical Finite Element Analysis of Lumbar Disc Herniation in Middle Aged and Elderly.Journal of healthcare engineering · 2022Article
- Article
- Posterior spinal instrumentation and decompression with or without cross-link?North American Spine Society journal · 2021Article
- Can cavity-based pedicle screw augmentation decrease screw loosening? A biomechanical in vitro study.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2021Article
- Prediction of complications and fusion outcomes of fused lumbar spine with or without fixation system under whole-body vibration.Medical & biological engineering & computing · 2021Article
- Cortical threaded pedicle screw improves fatigue strength in decreased bone quality.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2021Article
- Novel augmentation technique of percutaneous pedicle screw fixation using hydroxyapatite granules in the osteoporotic lumbar spine: a cadaveric biomechanical analysis.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2021Article
- [Techniques to increase pedicle screw stability in osteoporotic vertebrae].Operative Orthopadie und Traumatologie · 2019Review
- Complex spine deformities in young patients with severe osteogenesis imperfecta: current concepts review.Journal of children's orthopaedics · 2019Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeFor the stabilization of the thoracolumbar spine area, various stabilization techniques have been developed in recent decades. The aim of these techniques is to immobilize the treated segment to repositioning or correct the spine and guaranty long-term stability to achieve a reliable fusion. The aim of this study was to simulate in an in vitro experiment the postoperative long-term situation in elderly osteoporotic patients to compare two different stabilization principles; a pedicle screw system and a lamina hook system.
methodsTwo comparable groups with respect to age and bone mineral density with each n = 6 fresh-frozen human, bi-segmental thoracolumbar spine specimens (T11-L1) were used. Antero-posterior and lateral radiographs were taken before the test, to assess the spinal status. Then the intact specimens were biomechanically characterized with pure moments in the three anatomical planes in different states in terms of range of motion and neutral zone. After implantation of either, a pedicle screw system or a lamina hook system, the primary stability was determined under the same conditions. Subsequently the specimens were cyclically loaded under complex loading, using a custom-made set-up in a dynamic materials testing machine with increasing moments from 3 to 66 Nm until 100,000 cycles or until one of the three defined "failure" criteria was reached. (1) A failure of a bony structure. (2) Exceeding of the threefold ROM of the primary stability after implantation in flexion plus extension. (3) Reaching of the ROM based on the intact state before implantation both in flexion plus extension.
resultsThe results showed that the ROM was strongly reduced after instrumentation similar for both implant systems in all motion planes. The highest stabilization was found in flexion/extension. During cyclic loading with increasing moments, the ROM increased continuously for both systems. The number of load cycles until one of the failure criteria was reached varied only slightly between the two groups. In the pedicle screw group 30,000 (median) loading cycles (range 5000-80,000) with a corresponding moment of 24 Nm (range 9-54) could be reached. In the lamina hook group 32,500 load cycles (range 20,000-45,000) could be achieved with a corresponding moment of 25.5 Nm (range 18-33). There was a slight trend that the pedicle screw system is influenced more by bone mineral density.
conclusionBoth implant systems provide similar primary stability and similar long-term stability. In the pedicle screw group, there was a stronger correlation between bone mineral density and the reached number of load cycles.