Evidence map›Paper›PMID 27403224›Full record

ArticleJournal of vascular and interventional neurology2016

Small Intracranial Aneurysm Treatment Using Target (®) Ultrasoft (™) Coils.

Gaurav Jindal, Timothy Miller, Moronke Iyohe, Ravi Shivashankar, Vikram Prasad, Dheeraj Gandhi

Open access · greenAbstract read
In one paragraph

Article in Journal of vascular and interventional neurology, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.2field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 5 citations in OpenAlex.

  1. Trial
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Gaurav JindalDepartment of Interventional Neuroradiology, University of Maryland Medical Center, 22 South Greene Street, Baltimore, MD 21201, USA.
Timothy MillerDepartment of Interventional Neuroradiology, University of Maryland Medical Center, 22 South Greene Street, Baltimore, MD 21201, USA.
Moronke IyoheDepartment of Interventional Neuroradiology, University of Maryland Medical Center, 22 South Greene Street, Baltimore, MD 21201, USA.
Ravi ShivashankarDepartment of Interventional Neuroradiology, University of Maryland Medical Center, 22 South Greene Street, Baltimore, MD 21201, USA.
Vikram PrasadDepartment of Interventional Neuroradiology, University of Maryland Medical Center, 22 South Greene Street, Baltimore, MD 21201, USA.
Dheeraj GandhiDepartment of Interventional Neuroradiology, University of Maryland Medical Center, 22 South Greene Street, Baltimore, MD 21201, USA.
University of Maryland, Baltimore · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe introduction of small, soft, complex-shaped microcoils has helped facilitate the endovascular treatment of small intracranial aneurysms (IAs) over the last several years. Here, we evaluate the initial safety and efficacy of treating small IAs using only Target(®) Ultrasoft(™) coils. MATERIALS AND

methodsA retrospective review of a prospectively maintained clinical database at a single, high volume, teaching hospital was performed from September 2011 to May 2015. IAs smaller than or equal to 5.0 mm in maximal dimension treated with only Target(®) Ultrasoft(™) coils were included.

resultsA total of 50 patients with 50 intracranial aneurysms were included. Subarachnoid hemorrhage from index aneurysm rupture was the indication for treatment in 23 of 50 (46%) cases, and prior subarachnoid hemorrhage (SAH) from another aneurysm was the indication for treatment in eight of 50 (16%) cases. The complete aneurysm occlusion rate was 70% (35/50), the minimal residual aneurysm rate was 14% (7/50), and residual aneurysm rate was 16% (8/50). One intraoperative aneurysm rupture occurred. Three patients died during hospitalization from clinical sequelae of subarachnoid hemorrhage. Follow-up at a mean of 13.6 months demonstrated complete aneurysm occlusion in 75% (30/40) of cases, near complete occlusion in 15% (6/40) of cases, and residual aneurysm in 10% (4/40) of cases, all four of which were retreated.

conclusionOur initial results using only Target(®) Ultrasoft(™) coils for the endovascular treatment of small intracranial aneurysms demonstrate initial excellent safety and efficacy profiles.

Identifiers

PMID27403224
PMCPMC4925766
OpenAlexW2491438710

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.