Evidence map›Paper›PMID 27399790›Full record

ArticleBiosensors2016

Enhanced Biosensor Platforms for Detecting the Atherosclerotic Biomarker VCAM1 Based on Bioconjugation with Uniformly Oriented VCAM1-Targeting Nanobodies.

Duy Tien Ta, Wanda Guedens, Tom Vranken, Katrijn Vanschoenbeek, Erik Steen Redeker, Luc Michiels, Peter Adriaensens

Open access · goldAbstract read
In one paragraph

Article in Biosensors, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
2.6field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 23 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
  4. Recombinant antibodies and their use for food immunoanalysis.Analytical and bioanalytical chemistry · 2022
    Review
  5. Direct Immobilization of Engineered Nanobodies on Gold Sensors.ACS applied materials & interfaces · 2021
    Article
  6. Review
  7. Article
  8. Review
  9. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 3 countries.

Duy Tien TaBiomolecule Design Group, Institute for Materials Research (IMO), Hasselt University, Diepenbeek BE-3590, Belgium. duytien.ta@uhasselt.be.
Wanda GuedensBiomolecule Design Group, Institute for Materials Research (IMO), Hasselt University, Diepenbeek BE-3590, Belgium. tdtien@ctuet.edu.vn.
Tom VrankenBiomolecule Design Group, Institute for Materials Research (IMO), Hasselt University, Diepenbeek BE-3590, Belgium. wanda.guedens@uhasselt.be.
Katrijn VanschoenbeekImmunology and Biochemistry, Biomedical Research Institute (Biomed) and School of Life Sciences, Transnationale Universiteit Limburg, Hasselt University, Diepenbeek BE-3590, Belgium. katrijn.vanschoenbeek@uhasselt.be.
Erik Steen RedekerMaastricht Science Programme, Maastricht University, Maastricht 6200 MD, The Netherlands. erik.steenredeker@maastrichtuniversity.nl.
Luc MichielsImmunology and Biochemistry, Biomedical Research Institute (Biomed) and School of Life Sciences, Transnationale Universiteit Limburg, Hasselt University, Diepenbeek BE-3590, Belgium. luc.michiels@uhasselt.be.
Peter AdriaensensBiomolecule Design Group, Institute for Materials Research (IMO), Hasselt University, Diepenbeek BE-3590, Belgium. peter.adriaensens@uhasselt.be.
Hasselt University · BECan Tho University · VNMaastricht University · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Surface bioconjugation of biomolecules has gained enormous attention for developing advanced biomaterials including biosensors. While conventional immobilization (by physisorption or covalent couplings using the functional groups of the endogenous amino acids) usually results in surfaces with low activity, reproducibility and reusability, the application of methods that allow for a covalent and uniformly oriented coupling can circumvent these limitations. In this study, the nanobody targeting Vascular Cell Adhesion Molecule-1 (NbVCAM1), an atherosclerotic biomarker, is engineered with a C-terminal alkyne function via Expressed Protein Ligation (EPL). Conjugation of this nanobody to azidified silicon wafers and Biacore™ C1 sensor chips is achieved via Copper(I)-catalyzed azide-alkyne cycloaddition (CuAAC) "click" chemistry to detect VCAM1 binding via ellipsometry and surface plasmon resonance (SPR), respectively. The resulting surfaces, covered with uniformly oriented nanobodies, clearly show an increased antigen binding affinity, sensitivity, detection limit, quantitation limit and reusability as compared to surfaces prepared by random conjugation. These findings demonstrate the added value of a combined EPL and CuAAC approach as it results in strong control over the surface orientation of the nanobodies and an improved detecting power of their targets-a must for the development of advanced miniaturized, multi-biomarker biosensor platforms.

Indexed as

BiomarkersBiosensing TechniquesSingle-Domain AntibodiesVascular Cell Adhesion Molecule-1AntigensAtherosclerosisBuffersHumansProtein BindingSiliconSurface Plasmon ResonanceAntigensBiomarkersBuffersSiliconSingle-Domain AntibodiesVascular Cell Adhesion Molecule-1biosensorCuAACexpressed protein ligationuniformly oriented bioconjugationVCAM1-targeting nanobody

Identifiers

PMID27399790
PMCPMC5039653
OpenAlexW2464090701

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.