Evidence map›Paper›PMID 27391952›Full record

ArticlePloS one2016

Mechanical Ventilation Alters the Development of Staphylococcus aureus Pneumonia in Rabbit.

Saber-Davide Barbar, Laure-Anne Pauchard, Rémi Bruyère, Caroline Bruillard, Davy Hayez, Delphine Croisier, Jérôme Pugin, Pierre-Emmanuel Charles

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
2.0field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Bacterial andFrontiers in immunology · 2018
    Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 2 countries.

Saber-Davide BarbarLaboratoire "Ventilation Immunité Poumon", Pôle Microbiologie Environnementale et Risque Sanitaire (M.E.R.S.), U.M.R. 1347, I.N.R.A., Université de Bourgogne, Dijon, France.
Laure-Anne PauchardLaboratoire "Ventilation Immunité Poumon", Pôle Microbiologie Environnementale et Risque Sanitaire (M.E.R.S.), U.M.R. 1347, I.N.R.A., Université de Bourgogne, Dijon, France.
Rémi BruyèreLaboratoire "Ventilation Immunité Poumon", Pôle Microbiologie Environnementale et Risque Sanitaire (M.E.R.S.), U.M.R. 1347, I.N.R.A., Université de Bourgogne, Dijon, France.
Caroline BruillardLaboratoire "Ventilation Immunité Poumon", Pôle Microbiologie Environnementale et Risque Sanitaire (M.E.R.S.), U.M.R. 1347, I.N.R.A., Université de Bourgogne, Dijon, France.
Davy HayezVivexia S.A.R.L., Gemeaux, France.
Delphine CroisierVivexia S.A.R.L., Gemeaux, France.
Jérôme PuginIntensive Care Laboratory, University Hospitals of Geneva, and Department of Microbiology and Molecular Medicine, Faculty of Medicine, 1211 Geneva 14, Switzerland.
Pierre-Emmanuel CharlesLaboratoire "Ventilation Immunité Poumon", Pôle Microbiologie Environnementale et Risque Sanitaire (M.E.R.S.), U.M.R. 1347, I.N.R.A., Université de Bourgogne, Dijon, France.
Université de Bourgogne · FRAgroécologie · FRUniversity Hospital of Geneva · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Ventilator-associated pneumonia (VAP) is common during mechanical ventilation (MV). Beside obvious deleterious effects on muco-ciliary clearance, MV could adversely shift the host immune response towards a pro-inflammatory pattern through toll-like receptor (TLRs) up-regulation. We tested this hypothesis in a rabbit model of Staphylococcus aureus VAP. Pneumonia was caused by airway challenge with S. aureus, in either spontaneously breathing (SB) or MV rabbits (n = 13 and 17, respectively). Pneumonia assessment regarding pulmonary and systemic bacterial burden, as well as inflammatory response was done 8 and 24 hours after S. aureus challenge. In addition, ex vivo stimulations of whole blood taken from SB or MV rabbits (n = 7 and 5, respectively) with TLR2 agonist or heat-killed S. aureus were performed. Data were expressed as mean±standard deviation. After 8 hours of infection, lung injury was more severe in MV animals (1.40±0.33 versus [vs] 2.40±0.55, p = 0.007), along with greater bacterial concentrations (6.13±0.63 vs. 4.96±1.31 colony forming units/gram, p = 0.002). Interleukin (IL)-8 and tumor necrosis factor (TNF)-αserum concentrations reached higher levels in MV animals (p = 0.010). Whole blood obtained from MV animals released larger amounts of cytokines if stimulated with TLR2 agonist or heat-killed S. aureus (e.g., TNF-α: 1656±166 vs. 1005±89; p = 0.014). Moreover, MV induced TLR2 overexpression in both lung and spleen tissue. MV hastened tissue injury, impaired lung bacterial clearance, and promoted a systemic inflammatory response, maybe through TLR2 overexpression.

Indexed as

Respiration, ArtificialAnimalsInterleukin-8Pneumonia, StaphylococcalPneumonia, Ventilator-AssociatedRabbitsStaphylococcus aureusToll-Like Receptor 2Tumor Necrosis Factor-alphaInterleukin-8Toll-Like Receptor 2Tumor Necrosis Factor-alpha

Identifiers

PMID27391952
PMCPMC4938582
OpenAlexW2467087069

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.