Evidence map›Paper›PMID 27391895›Full record

ArticlePloS one2016

A Comparison of Biocompatibility of a Titanium Alloy Fabricated by Electron Beam Melting and Selective Laser Melting.

Hong Wang, Bingjing Zhao, Changkui Liu, Chao Wang, Xinying Tan, Min Hu

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
20citing papers in PubMed, 1 pooled it
5.3field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

20 citing papers in PubMed, 1 synthesis or guideline pooled it, 83 citations in OpenAlex.

  1. 3D-printed spine surgery implants: a systematic review of the efficacy and clinical safety profile of patient-specific and off-the-shelf devices.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2020
    Pooled it
  2. Article
  3. In Vivo Study of Bone Growth Around Additively Manufactured Implants With Ti-6Al-4V and Bioactive Glass Powder Composites.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2025
    Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Review
  10. Article
  11. Review
  12. Review
  13. Review
  14. Article
  15. Article
  16. Article
  17. Review
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Hong WangDepartment of Stomatology, General Hospital of the People's Libration Army, Beijing, China.
Bingjing ZhaoDepartment of Stomatology, General Hospital of the People's Libration Army, Beijing, China.
Changkui LiuDepartment of Stomatology, the 451th Hospital of the People's Libration Army, Xi'an, China.
Chao WangSchool of Medicine, Nankai University, Tianjin, China.
Xinying TanDepartment of Stomatology, the 304th Hospital of the People's Libration Army, Beijing, China.
Min HuDepartment of Stomatology, General Hospital of the People's Libration Army, Beijing, China.
Jinzhou Medical University · CNFirst Affiliated Hospital of Chinese PLA General Hospital · CNNankai University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Electron beam melting (EBM) and selective laser melting (SLM) are two advanced rapid prototyping manufacturing technologies capable of fabricating complex structures and geometric shapes from metallic materials using computer tomography (CT) and Computer-aided Design (CAD) data. Compared to traditional technologies used for metallic products, EBM and SLM alter the mechanical, physical and chemical properties, which are closely related to the biocompatibility of metallic products. In this study, we evaluate and compare the biocompatibility, including cytocompatibility, haemocompatibility, skin irritation and skin sensitivity of Ti6Al4V fabricated by EBM and SLM. The results were analysed using one-way ANOVA and Tukey's multiple comparison test. Both the EBM and SLM Ti6Al4V exhibited good cytobiocompatibility. The haemolytic ratios of the SLM and EBM were 2.24% and 2.46%, respectively, which demonstrated good haemocompatibility. The EBM and SLM Ti6Al4V samples showed no dermal irritation when exposed to rabbits. In a delayed hypersensitivity test, no skin allergic reaction from the EBM or the SLM Ti6Al4V was observed in guinea pigs. Based on these results, Ti6Al4V fabricated by EBM and SLM were good cytobiocompatible, haemocompatible, non-irritant and non-sensitizing materials. Although the data for cell adhesion, proliferation, ALP activity and the haemolytic ratio was higher for the SLM group, there were no significant differences between the different manufacturing methods.

Indexed as

ElectronsLasersAlloysAnimalsCell ProliferationCells, CulturedCell SurvivalDogsGuinea PigsMaterials TestingMicroscopy, Electron, ScanningOsteogenesisRabbitsSkinSurface PropertiesTitaniumAlloysTitaniumtitanium alloy (TiAl6V4)

Identifiers

PMID27391895
PMCPMC4938601
OpenAlexW2461855259

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked