Evidence map›Paper›PMID 27391328›Full record

ArticlePloS one2016

Comparative Analysis of the Biomechanical Behaviour of Two Cementless Short Stems for Hip Replacement: Linea Anatomic and Minihip.

Sergio Gabarre, Antonio Herrera, Elena Ibarz, Jesús Mateo, Jorge Gil-Albarova, Luis Gracia

Open access · goldAbstract readComparative Study
In one paragraph

Article in PloS one, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
1.9field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 20 citations in OpenAlex.

  1. Stem length in primary cementless total hip arthroplasty: Does it make a difference in bone remodeling?European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2019
    Trial
  2. Medium-term outcome of the LibraBMC musculoskeletal disorders · 2023
    Article
  3. Article
  4. Article
  5. Article
  6. High prevalence and undertreatment of osteoporosis in elderly patients undergoing total hip arthroplasty.Osteoporosis international : a journal established as result of cooperation between the European Foundation for Osteoporosis and the National Osteoporosis Foundation of the USA · 2021
    Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Sergio GabarreDepartment of Mechanical Engineering, University of Zaragoza, Zaragoza, Spain.
Antonio HerreraDepartment of Surgery, University of Zaragoza, Zaragoza, Spain.
Elena IbarzDepartment of Mechanical Engineering, University of Zaragoza, Zaragoza, Spain.
Jesús MateoDepartment of Surgery, University of Zaragoza, Zaragoza, Spain.
Jorge Gil-AlbarovaDepartment of Surgery, University of Zaragoza, Zaragoza, Spain.
Luis GraciaDepartment of Mechanical Engineering, University of Zaragoza, Zaragoza, Spain.
Universidad de Zaragoza · ESInstituto de Investigación Sanitaria Aragón · ESHospital Universitario Miguel Servet · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A comparative study between two stems (Linea Anatomic and Minihip) has been performed in order to analyse the differences in their biomechanical behaviour, concerning stem micromotions and load transmission between stem and bone. From the corresponding finite element models, a parametric study was carried out to quantify ranges of micromotions taking into account: friction coefficient in the stem-bone interface, press-fit and two types of gait cycle. Micromotions were evaluated for each stem at six different levels along repeated gait cycles. An initial and marked stem subsidence at the beginning of the simulation was observed, followed by an asymptotic decrease due to friction forces. Once migration occurs, a repeated reversible cyclic micromotion is developed and stabilized as gait cycle times are simulated. The general motion pattern exhibited higher amplitude of micromotion for Minihip compared to Linea stem. The load transmission mechanism was analyzed, identifying the main internal forces. The results show higher local forces for Minihip stem up to 80% greater than for Linea stem. The differences of design between Minihip and Linea conditioned different distributions of load, influencing the posterior stress-shielding. Consequently, short stems require high bone stock and quality should, being indicated for young patients with high bone quality.

Indexed as

Bone-Implant InterfaceGaitHip ProsthesisModels, BiologicalFrictionHumansStress, MechanicalWeight-Bearing

Identifiers

PMID27391328
PMCPMC4938462
OpenAlexW2472400920

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.