ReviewKorean journal of radiology
Hemodynamic Measurement Using Four-Dimensional Phase-Contrast MRI: Quantification of Hemodynamic Parameters and Clinical Applications.
Review in Korean journal of radiology. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
18 citing papers in PubMed.
- Revolutionizing vascular imaging: trends and future directions of 4D flow MRI based on a 20-year bibliometric analysis.Quantitative imaging in medicine and surgery · 2024Article
- Segmentation of the aorta in systolic phase from 4D flow MRI: multi-atlas vs. deep learning.Magma (New York, N.Y.) · 2023Article
- Value of clinical applications of differential pressure and relative pressure imaging in the left ventricle.World journal of clinical cases · 2023Review
- Distribution and regional variation of wall shear stress in the curved middle cerebral artery using four-dimensional flow magnetic resonance imaging.Quantitative imaging in medicine and surgery · 2022Article
- Whole-Heart 4D Flow MRI for Evaluation of Normal and Regurgitant Valvular Flow: A Quantitative Comparison Between Pseudo-Spiral Sampling and EPI Readout.Journal of magnetic resonance imaging : JMRI · 2022Article
- Technical Background for 4D Flow MR Imaging.Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine · 2022Article
- Intracranial Flow Velocity Quantification Using Non-Contrast Four-Dimensional Flow MRI: A Prospective Comparative Study with Transcranial Doppler Ultrasound.Diagnostics (Basel, Switzerland) · 2021Article
- Improving Blood Flow Visualization of Recirculation Regions at Carotid Bulb in 4D Flow MRI Using Semi-Automatic Segmentation with ITK-SNAP.Diagnostics (Basel, Switzerland) · 2021Article
- [The preliminary value of vector flow mapping on assessment of left intraventricular pressure difference in patients with paroxysmal atrial fibrillation].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2021Article
- Comparison of Hemodynamic Visualization in Cerebral Arteries: Can Magnetic Resonance Imaging Replace Computational Fluid Dynamics?Journal of personalized medicine · 2021Article
- Article
- [Cardiac magnetic resonance imaging : Trends and developments].Der Radiologe · 2020Review
- 4D flow imaging of the thoracic aorta: is there an added clinical value?Cardiovascular diagnosis and therapy · 2020Review
- Biomechanical Forces and Atherosclerosis: From Mechanism to Diagnosis and Treatment.Current cardiology reviews · 2020Review
- Four-Dimensional Flow Magnetic Resonance Imaging for Assessment of Velocity Magnitudes and Flow Patterns in The Human Carotid Artery Bifurcation: Comparison with Computational Fluid Dynamics.Diagnostics (Basel, Switzerland) · 2019Article
- Article
- The Advantages of Viscous Dissipation Rate over Simplified Power Loss as a Fontan Hemodynamic Metric.Annals of biomedical engineering · 2018Article
- Whence we came, whither we go?The international journal of cardiovascular imaging · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Recent improvements have been made to the use of time-resolved, three-dimensional phase-contrast (PC) magnetic resonance imaging (MRI), which is also named four-dimensional (4D) PC-MRI or 4D flow MRI, in the investigation of spatial and temporal variations in hemodynamic features in cardiovascular blood flow. The present article reviews the principle and analytical procedures of 4D PC-MRI. Various fluid dynamic biomarkers for possible clinical usage are also described, including wall shear stress, turbulent kinetic energy, and relative pressure. Lastly, this article provides an overview of the clinical applications of 4D PC-MRI in various cardiovascular regions.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials