Evidence map›Paper›PMID 27369636›Full record

ArticleJournal of orthopaedic surgery and research2016

Biomechanical effects of morphological variations of the cortical wall at the bone-cement interface.

Chun-Lin Zhang, Guo-Qi Shen, Kun-Peng Zhu, Dong-Xu Liu

Abstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Chun-Lin ZhangDepartment of Orthopaedic Surgery, the Tenth People's Hospital Affiliated to Tongji University, #301 Yan-chang Middle Road, Shanghai, 200072, China. shzhangchunlin@163.com.
Guo-Qi ShenDepartment of Orthopaedic Surgery, Changshu Second People's Hospital, Changshu, 215500, China.
Kun-Peng ZhuDepartment of Orthopaedic Surgery, The Sixth People's Hospital Affiliated to Shanghai Jiaotong University, Shanghai, 200233, China.
Dong-Xu LiuOrthotek Lab, School of Mechatronics Engineering and Automation, Shanghai University, No. 149, Yanchang Rd, 200072, Shanghai, People's Republic of China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe integrity of bone-cement interface is very important for the stabilization and long-term sustain of cemented prosthesis. Variations in the bone-cement interface morphology may affect the mechanical response of the shape-closed interlock.

methodsSelf-developed new reamer was used to process fresh pig reamed femoral canal, creating cortical grooves in the canal wall of experimental group. The biomechanical effects of varying the morphology with grooves of the bone-cement interface were investigated using finite element analysis (FEA) and validated using companion experimental data. Micro-CT scans were used to document interlock morphology.

resultsThe contact area of the bone-cement interface was greater (P < 0.05) for the experimental group (5470 ± 265 mm(2)) when compared to the specimens of control group (5289 ± 299 mm(2)). The mechanical responses to tensile loading and anti-torsion showed that the specimens with grooves were stronger (P < 0.05) at the bone-cement interface than the specimens without grooves. There were positively significant correlation between the contact area and the tensile force (r (2) = 0.85) and the maximal torsion (r (2) = 0.77) at the bone-cement interface. The volume of cement of the experimental group (7688 ± 278 mm(3)) was greater (P < 0.05) than of the control group (5764 ± 186 mm(3)). There were positively significant correlations between the volume of cement and the tensile force (r (2) = 0.90) and the maximal torsion (r (2) = 0.97) at the bone-cement interface. The FEA results compared favorably to the tensile and torsion relationships determined experimentally. More cracks occurred in the cement than in the bone.

conclusionsConverting the standard reaming process from a smooth bore cortical tube to the one with grooves permits the cement to interlock with the reamed bony wall. This would increase the strength of the bone-cement interface.

Indexed as

Bone CementsAnimalsBiomechanical PhenomenaCementationFemurMaterials TestingSwineTomography, Spiral ComputedBone CementsBiomechanicsBone cementInterfaceMorphology

Identifiers

PMID27369636
PMCPMC4929745

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.