Evidence map›Paper›PMID 27368012›Full record

Trial reportMedicine2016

Double-low protocol for hepatic dynamic CT scan: Effect of low tube voltage and low-dose iodine contrast agent on image quality.

Xiuli Zhang, Shaodong Li, Wenlou Liu, Ning Huang, Jingjing Li, Li Cheng, Kai Xu

Abstract readRandomized Controlled Trial
In one paragraph

Trial report in Medicine, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Xiuli ZhangaDepartment of Radiology, Affiliated Hospital of Xuzhou Medical University bSchool of Medical Imaging, Xuzhou Medical University, Xuzhou cDepartment of Oncology, Zhongnan Hospital of Wuhan University, Wuhan dGE Life Science, Beijing, P. R. China.
Shaodong Li
Wenlou Liu
Ning Huang
Jingjing Li
Li Cheng
Kai Xu

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The radiation-induced carcinogenesis from computed tomography (CT) and iodine contrast agent induced nephropathy has attracted international attention. The reduction of the radiation dose and iodine intake in CT scan is always a direction for researchers to strive. The purpose of this study was to evaluate the feasibility of a "double-low" (i.e., low tube voltage and low-dose iodine contrast agent) scanning protocol for dynamic hepatic CT with the adaptive statistical iterative reconstruction (ASIR) in patients with a body mass index (BMI) of 18.5 to 27.9 kg/m.A total of 128 consecutive patients with a BMI between 18.5 and 27.9 kg/m were randomly assigned into 3 groups according to tube voltage, iodine contrast agent, and reconstruction algorithms. Group A (the "double-low" protocol): 100 kVp tube voltage with 40% ASIR, iodixanol at 270 mg I/mL, group B: 120 kVp tube voltage with filtered back projection (FBP), iodixanol at 270 mg I/ mL, and group C: 120 kVp tube voltage with FBP, ioversol at 350 mg I/ mL.The volume CT dose index (CTDIvol) and effective dose (ED) in group A were lower than those in group B and C (all P < 0.01). The iodine intake in group A was decreased by approximately 26.5% than group C, whereas no statistical difference was observed between group A and B (P > 0.05). There was no significant difference of the CT values between group A and C (P > 0.05), which both showed higher CT values than that in group B (P < 0.001). However, no statistic difference was observed in the contrast-to-noise ratio (CNR), the signal-to-noise ratio (SNR), and image-quality scores among the 3 groups (all P > 0.05). Near-perfect consistency of the evaluation for group A, B, and C (Kenall's W = 0.921, 0.874, and 0.949, respectively) was obtained by the 4 readers with respect to the overall image quality.These results suggested that the "double-low" protocol with ASIR algorithm for multi-phase hepatic CT scan can dramatically decrease radiation dose and iodine intake with adequate image quality in patients with BMI of 18.5 to 27.9 kg/m.

Indexed as

AdultAgedAged, 80 and overClinical ProtocolsContrast MediaFemaleHumansImage EnhancementIodineLiverMaleMiddle AgedProspective StudiesRadiation DosageTomography, X-Ray ComputedTriiodobenzoic AcidsContrast MediaIodineiodixanolTriiodobenzoic Acids

Identifiers

PMID27368012
PMCPMC4937926

What OpenQuestion holds

Textmetadata
LicenceCC BY-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.