Parallax error in long-axial field-of-view PET scanners-a simulation study.
Article in Physics in medicine and biology, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 27 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
27 citing papers in PubMed.
- Realization of long axial field-of-view PET technology in the clinic and research environment.The British journal of radiology · 2026Review
- Impact of the maximum ring difference on image quality and noise characteristics of a total-body PET/CT scanner.Zeitschrift fur medizinische Physik · 2025Article
- Performance evaluation of a medium axial field-of-view sparse PET system based on flat panels of monolithic LYSO detectors: a simulation study.EJNMMI physics · 2025Article
- A Time-Walk and Timing-Shift Correction Method for Dual-Ended Readout TOF-DOI PET Detectors.IEEE transactions on radiation and plasma medical sciences · 2025Article
- Total Body PET/CT: Future Aspects.Seminars in nuclear medicine · 2025Review
- Development of Whole-Body TOF-DOI PET Detector Using Dual-Ended Readout Method.IEEE transactions on instrumentation and measurement · 2025Article
- 3D in-system calibration method for PET detectors.Medical physics · 2025Article
- A simulation study of the system characteristics for a long axial FOV PET design based on monolithic BGO flat panels compared with a pixelated LSO cylindrical design.EJNMMI physics · 2023Article
- Timing, Energy, and Spatial Characterization of Highly Sampled Monolithic PET Detectors with Different Thicknesses.IEEE transactions on radiation and plasma medical sciences · 2023Article
- Monte Carlo simulation of the system performance of a long axial field-of-view PET based on monolithic LYSO detectors.EJNMMI physics · 2023Article
- Characterization of the partial volume effect along the axial field-of-view of the Biograph Vision Quadra total-body PET/CT system for multiple isotopes.EJNMMI physics · 2023Article
- Total-body PET: a new paradigm for molecular imaging.The British journal of radiology · 2022Review
- An encoder-decoder network for direct image reconstruction on sinograms of a long axial field of view PET.European journal of nuclear medicine and molecular imaging · 2022Article
- Optimizing acquisition times for total-body positron emission tomography/computed tomography with half-doseEJNMMI physics · 2022Article
- High-resolution and high-sensitivity PET for quantitative molecular imaging of the monoaminergic nuclei: A GATE simulation study.Medical physics · 2022Article
- Performance Characteristics of Long Axial Field-of-View PET Scanners with Axial Gaps.IEEE transactions on radiation and plasma medical sciences · 2021Article
- 3D/4D Reconstruction and Quantitative Total Body Imaging.PET clinics · 2021Review
- Scanner Design Considerations for Long Axial Field-of-View PET Systems.PET clinics · 2021Review
- State of the art in total body PET.EJNMMI physics · 2020Review
- Performance Evaluation of a Newly Developed MR-Compatible Mobile PET Scanner with Two Detector Layouts.Molecular imaging and biology · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
There is a growing interest in the design and construction of a PET scanner with a very long axial extent. One critical design challenge is the impact of the long axial extent on the scanner spatial resolution properties. In this work, we characterize the effect of parallax error in PET system designs having an axial field-of-view (FOV) of 198 cm (total-body PET scanner) using fully-3D Monte Carlo simulations. Two different scintillation materials were studied: LSO and LaBr
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.