Evidence map›Paper›PMID 27365325›Full record

ArticleAJNR. American journal of neuroradiology2016

Virtual-versus-Real Implantation of Flow Diverters: Clinical Potential and Influence of Vascular Geometry.

P Bouillot, O Brina, H Yilmaz, M Farhat, G Erceg, K-O Lovblad, M I Vargas, Z Kulcsar, V M Pereira

Open access · hybridAbstract read
In one paragraph

Article in AJNR. American journal of neuroradiology, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed, 1 pooled it
1.6field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 1 synthesis or guideline pooled it, 22 citations in OpenAlex.

  1. Pooled it
  2. Virtual implantation of Derivo Embolization Devices using PreSize Neurovascular software: Accuracy evaluation and size selection comparison study.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2026
    Article
  3. PREDICT: Precise deployment of Silk Vista Baby in confined territory: A technical note.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2026
    Article
  4. Article
  5. Verification of software-based preoperative simulation of flow diverters in clinical cases.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2023
    Article
  6. Article
  7. A novel virtual flow diverter implantation method with realistic deployment mechanics and validated force response.International journal for numerical methods in biomedical engineering · 2020
    Article
  8. Article
  9. Article
  10. Review
  11. Article
  12. Entry remnants in flow-diverted aneurysms: Does branch geometry influence aneurysm closure?Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2018
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 3 countries.

P BouillotFrom the Division of Neuroradiology (P.B., O.B., H.Y., G.E., K.-O.L., M.I.V., Z.K.), University Hospitals of Geneva, Geneva, Switzerland.ORCID http://orcid.org/0000-0002-4964-8022
O BrinaFrom the Division of Neuroradiology (P.B., O.B., H.Y., G.E., K.-O.L., M.I.V., Z.K.), University Hospitals of Geneva, Geneva, Switzerland.ORCID http://orcid.org/0000-0003-1712-0124
H YilmazFrom the Division of Neuroradiology (P.B., O.B., H.Y., G.E., K.-O.L., M.I.V., Z.K.), University Hospitals of Geneva, Geneva, Switzerland.ORCID http://orcid.org/0000-0003-4678-5045
M FarhatLaboratory for Hydraulic Machines (P.B., M.F.), École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland.ORCID http://orcid.org/0000-0002-4782-2170
G ErcegFrom the Division of Neuroradiology (P.B., O.B., H.Y., G.E., K.-O.L., M.I.V., Z.K.), University Hospitals of Geneva, Geneva, Switzerland.ORCID http://orcid.org/0000-0003-0193-3585
K-O LovbladFrom the Division of Neuroradiology (P.B., O.B., H.Y., G.E., K.-O.L., M.I.V., Z.K.), University Hospitals of Geneva, Geneva, Switzerland.ORCID http://orcid.org/0000-0003-2768-9779
M I VargasFrom the Division of Neuroradiology (P.B., O.B., H.Y., G.E., K.-O.L., M.I.V., Z.K.), University Hospitals of Geneva, Geneva, Switzerland.ORCID http://orcid.org/0000-0002-6571-5336
Z KulcsarFrom the Division of Neuroradiology (P.B., O.B., H.Y., G.E., K.-O.L., M.I.V., Z.K.), University Hospitals of Geneva, Geneva, Switzerland.ORCID http://orcid.org/0000-0002-6805-5150
V M PereiraDivision of Neuroradiology (V.M.P.), Department of Medical Imaging vitormpbr@hotmail.com.ORCID http://orcid.org/0000-0002-6804-3985
University Hospital of Geneva · CHÉcole Polytechnique Fédérale de Lausanne · CHUniversity Health Network · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background and purposeIntracranial stents have become extremely important in the endovascular management of complex intracranial aneurysms. Sizing and landing zone predictions are still very challenging steps in the procedure. Virtual stent deployment may help therapeutic planning, device choice, and hemodynamic simulations. We aimed to assess the predictability of our recently developed virtual deployment model by comparing in vivo and virtual stents implanted in a consecutive series of patients presenting with intracranial aneurysms. MATERIALS AND

methodsVirtual stents were implanted in patient-specific geometries of intracranial aneurysms treated with the Pipeline Embolization Device. The length and cross-section of virtual and real stents measured with conebeam CT were compared. The influence of vessel geometry modifications occurring during the intervention was analyzed.

resultsThe virtual deployment based on pre- and poststent implantation 3D rotational angiography overestimated (underestimated) the device length by 13% ± 11% (-9% ± 5%). These differences were highly correlated (

conclusionsThe recently proposed geometric model was shown to predict accurately the deployment of Pipeline Embolization Devices when the stent radius was well-assessed. However, unpredictable delivery manipulations and variations of vessel geometry occurring during the intervention might impact the stent implantation.