Evidence map›Paper›PMID 27365109›Full record

ArticleLasers in medical science2016

Temperature evaluation of dental implant surface irradiated with high-power diode laser.

F G Rios, E R Viana, G M Ribeiro, J C González, A Abelenda, D C Peruzzo

Abstract read
PubMed Publisher
In one paragraph

Article in Lasers in medical science, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
2.7field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 21 citations in OpenAlex.

  1. Trial
  2. Article
  3. Role of decontamination treatment for implant surface in the treatment of peri-implantitis.Zhong nan da xue xue bao. Yi xue ban = Journal of Central South University. Medical sciences · 2022
    Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

F G RiosCentro de Pesquisas Odontológicas São Leopoldo Mandic (SLMANDIC), Dental Research Center, Rua Dr. José Rocha Junqueira 13, Ponte Preta, Campinas, SP, Brazil. fernandorios@doctor.com.
E R VianaPhysics Department (DAFIS), Universidade Tecnológica Federal do Paraná (UTFPR), Av. Sete de Setembro 3165, Rebouças, Curitiba, PR, Brazil. emilsonjunior@utfpr.edu.br.
G M RibeiroPhysics Department, Universidade Federal de Minas Gerais (UFMG), Av. Presidente Antônio Carlos 6627, Pampulha, Belo Horizonte, MG, Brazil.
J C GonzálezPhysics Department, Universidade Federal de Minas Gerais (UFMG), Av. Presidente Antônio Carlos 6627, Pampulha, Belo Horizonte, MG, Brazil.
A AbelendaPhysics Department, Universidade Federal de Minas Gerais (UFMG), Av. Presidente Antônio Carlos 6627, Pampulha, Belo Horizonte, MG, Brazil.
D C PeruzzoCentro de Pesquisas Odontológicas São Leopoldo Mandic (SLMANDIC), Dental Research Center, Rua Dr. José Rocha Junqueira 13, Ponte Preta, Campinas, SP, Brazil.
Universidade Federal de Minas Gerais · BRFaculdade São Leopoldo Mandic · BRUniversidade Tecnológica Federal do Paraná · BR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The prevalence of peri-implantitis and the absence of a standard approach for decontamination of the dental implant surface have led to searches for effective therapies. Since the source of diode lasers is portable, has reduced cost, and does not cause damage to the titanium surface of the implant, high-power diode lasers have been used for this purpose. The effect of laser irradiation on the implants is the elevation of the temperature surface. If this elevation exceeds 47 °C, the bone tissue is irreversibly damaged, so for a safety therapy, the laser parameters should be controlled. In this study, a diode laser of GaAsAl was used to irradiate titanium dental implants, for powers 1.32 to 2.64 W (real) or 2.00 to 4.00 W (nominal), in continuous/pulsed mode DC/AC, with exposure time of 5/10 s, with/without air flow for cooling. The elevation of the temperature was monitored in real time in two positions: cervical and apical. The best results for decontamination using a 968-nm diode laser were obtained for a power of 1.65 and 1.98 W (real) for 10 s, in DC or AC mode, with an air flow of 2.5 l/min. In our perspective in this article, we determine a suggested approach for decontamination of the dental implant surface using a 968-nm diode laser.

Indexed as

Dental ImplantsTemperatureAnimalsDecontaminationLasers, SemiconductorPeri-ImplantitisSwineTitaniumDental ImplantsTitaniumDecontaminationDental implantsDiode laser irradiationGaAsAl laserPeriodontitisTemperature increase

Identifiers

PMID27365109
OpenAlexW2460939704

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.