ArticleJournal of medical case reports2016
Mechanical aortic valve without anticoagulation for 33 years in a Yemeni man: a case report.
Article in Journal of medical case reports, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 4 citations in OpenAlex.
- Article
- Article
- A 31-year-old patient without the use of warfarin and with an aortic mechanical valve.Anatolian journal of cardiology · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
1 author at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundMechanical prosthetic heart valves have been used for many decades to replace damaged native valves. Guidelines mandate the use of anticoagulant therapy in patients with mechanical prosthetic valves of any type, irrespective of the position in the heart. The rationale for this is to prevent valve thrombosis and thromboembolic complications without increasing the risk of excess bleeding. We report a case involving a patient with a functioning aortic mechanical valve without any anticoagulation therapy for 33 years. CASE PRESENTATION: A 46-year-old Yemeni man had an aortic valve replacement, using a St Jude Medical mechanical valve, 33 years ago due to aortic regurgitation grade III-IV of his native valve as a result of rheumatic heart disease. His anticoagulant therapy of Syncumar (acenocoumarol which is a derivative of coumarin) was discontinued 4 months after surgery, and he was sustained on aspirin and digoxin. He presented to our cardiac clinic 33 years later with palpitations, which had started 2 weeks previously. On clinical examination, his condition was fair with a New York Heart Association functional classification of I. He was in sinus rhythm and had normal heart size, as shown on chest X-ray. Echocardiography revealed normal heart chamber dimensions and normal left ventricular systolic and diastolic function. His mean transaortic gradient was 12.58 mmHg and the calculated aortic valve area was 1.44 cm(2). He was started on anticoagulant therapy.
conclusionsOnly a few cases of well-functioning mechanical valves without the use of anticoagulant therapy for many years have been reported. Our patient is one such case who used only aspirin for 33 years. Further research is needed to understand the interpersonal variations and other unexplored factors in anticoagulant therapy for patients with mechanical prosthetic heart valves.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.