Evidence map›Paper›PMID 27353266›Full record

ArticleAntimicrobial agents and chemotherapy2016

In Vitro and In Vivo Effectiveness of an Innovative Silver-Copper Nanoparticle Coating of Catheters To Prevent Methicillin-Resistant Staphylococcus aureus Infection.

Myriam K S Ballo, Sami Rtimi, César Pulgarin, Nancy Hopf, Aurélie Berthet, John Kiwi, Philippe Moreillon, José M Entenza, Alain Bizzini

Open access · bronzeAbstract read
In one paragraph

Article in Antimicrobial agents and chemotherapy, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
4.7field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 43 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Review
  6. Review
  7. Article
  8. Review
  9. Review
  10. Review
  11. Review
  12. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 1 country.

Myriam K S BalloDepartment of Fundamental Microbiology, University of Lausanne, Lausanne, Switzerland Group of Advanced Oxidation Processes, Swiss Federal Institute of Technology, EPFL-SB-ISIC-GPAO, Lausanne, Switzerland.
Sami RtimiGroup of Advanced Oxidation Processes, Swiss Federal Institute of Technology, EPFL-SB-ISIC-GPAO, Lausanne, Switzerland.ORCID 0000-0002-1924-3710
César PulgarinGroup of Advanced Oxidation Processes, Swiss Federal Institute of Technology, EPFL-SB-ISIC-GPAO, Lausanne, Switzerland.
Nancy HopfInstitute of Work and Health, University of Lausanne, Lausanne, Switzerland.
Aurélie BerthetInstitute of Work and Health, University of Lausanne, Lausanne, Switzerland.
John KiwiGroup of Advanced Oxidation Processes, Swiss Federal Institute of Technology, EPFL-SB-ISIC-GPAO, Lausanne, Switzerland.
Philippe MoreillonDepartment of Fundamental Microbiology, University of Lausanne, Lausanne, Switzerland.
José M EntenzaDepartment of Fundamental Microbiology, University of Lausanne, Lausanne, Switzerland jose.entenza@unil.ch.
Alain BizziniDepartment of Fundamental Microbiology, University of Lausanne, Lausanne, Switzerland.
École Polytechnique Fédérale de Lausanne · CHUniversity of Lausanne · CHInstitute for Work and Health · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In this study, silver/copper (Ag/Cu)-coated catheters were investigated for their efficacy in preventing methicillin-resistant Staphylococcus aureus (MRSA) infection in vitro and in vivo Ag and Cu were sputtered (67/33% atomic ratio) on polyurethane catheters by direct-current magnetron sputtering. In vitro, Ag/Cu-coated and uncoated catheters were immersed in phosphate-buffered saline (PBS) or rat plasma and exposed to MRSA ATCC 43300 at 10(4) to 10(8) CFU/ml. In vivo, Ag/Cu-coated and uncoated catheters were placed in the jugular vein of rats. Directly after, MRSA (10(7) CFU/ml) was inoculated in the tail vein. Catheters were removed 48 h later and cultured. In vitro, Ag/Cu-coated catheters preincubated in PBS and exposed to 10(4) to 10(7) CFU/ml prevented the adherence of MRSA (0 to 12% colonization) compared to uncoated catheters (50 to 100% colonization; P < 0.005) and Ag/Cu-coated catheters retained their activity (0 to 20% colonization) when preincubated in rat plasma, whereas colonization of uncoated catheters increased (83 to 100%; P < 0.005). Ag/Cu-coating protection diminished with 10(8) CFU/ml in both PBS and plasma (50 to 100% colonization). In vivo, Ag/Cu-coated catheters reduced the incidence of catheter infection compared to uncoated catheters (57% versus 79%, respectively; P = 0.16) and bacteremia (31% versus 68%, respectively; P < 0.05). Scanning electron microscopy of explanted catheters suggests that the suboptimal activity of Ag/Cu catheters in vivo was due to the formation of a dense fibrin sheath over their surface. Ag/Cu-coated catheters thus may be able to prevent MRSA infections. Their activity might be improved by limiting plasma protein adsorption on their surfaces.

Indexed as

AdsorptionAnimalsAnti-Infective AgentsBacteremiaCatheters, IndwellingCoated Materials, BiocompatibleColony Count, MicrobialCopperFibrinJugular VeinsMethicillin-Resistant Staphylococcus aureusNanoparticlesPolyurethanesRatsSilverStaphylococcal InfectionsAnti-Infective AgentsCoated Materials, BiocompatibleCopperFibrinPolyurethanesSilver

Identifiers

PMID27353266
PMCPMC4997872
OpenAlexW2471402583

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked