Electrophysiological detection of scalar changing perimodiolar cochlear electrode arrays: a long term follow-up study.

Philipp Mittmann, I Todt, A Ernst, G Rademacher, S Mutze, S Göricke, M Schlamann, R Ramalingam, S Lang, F Christov and 1 more

Registry-linked trialAbstract read
PubMed Publisher
In one paragraph

Article in European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03306108 (Correlation Between the Neural Response Telemetry), which is not on this map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT03306108 unknown statusnot on this mapstarted 2017, after this paper: background citation

Correlation Between the Neural Response Telemetry (NRT) and Radiological Measurements in Detection of Position of the Electrode Inside the Cochlea

TypeobservationalSponsorAssiut UniversityRan2017 to 2018Enrolled50ConditionsCochlear Function DisorderArmsNRT
3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. A systematic review of electrode array scalar dislocation after cochlear implant surgery.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2026
    Pooled it
  2. Article
  3. Article
  4. Electrophysiological detection of electrode fold-over in perimodiolar cochlear implant electrode arrays: a multi-center study case series.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2020
    Article
  5. Electrophysiological measurements with electrode types of different perimodiolar properties and the same cochlear implant electronics - a retrospective comparison study.Journal of otolaryngology - head & neck surgery = Le Journal d'oto-rhino-laryngologie et de chirurgie cervico-faciale · 2019
    Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Philipp MittmannDepartment of Otolaryngology, Unfallkrankenhaus Berlin (UKB), Warener Str. 7, 12683, Berlin, Germany. philipp.mittmann@googlemail.com.
I TodtDepartment of Otolaryngology, Unfallkrankenhaus Berlin (UKB), Warener Str. 7, 12683, Berlin, Germany.
A ErnstDepartment of Otolaryngology, Unfallkrankenhaus Berlin (UKB), Warener Str. 7, 12683, Berlin, Germany.
G RademacherDepartment of Radiology, UKB, Berlin, Germany.
S MutzeDepartment of Radiology, UKB, Berlin, Germany.
S GörickeDepartment of Neuroradiology and Radiology, University Hospital of Essen, University Duisburg-Essen, Essen, Germany.
M SchlamannDepartment of Neuroradiology and Radiology, University Hospital Giessen and Marburg GmbH, Marburg, Germany.
R RamalingamKKR ENT Hospital and Research Institute, Chennai, 600010, India.
S LangDepartment of Otolaryngology, Head and Neck Surgery, University Hospital of Essen, University Duisburg-Essen, Essen, Germany.
F ChristovDepartment of Otolaryngology, Head and Neck Surgery, University Hospital of Essen, University Duisburg-Essen, Essen, Germany.
D Arweiler-HarbeckDepartment of Otolaryngology, Head and Neck Surgery, University Hospital of Essen, University Duisburg-Essen, Essen, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The position of the cochlear electrode array within the scala tympani is essential for an optimal hearing benefit. An intraoperative NRT-ratio was established, which can provide information about the intraoperative intracochlear electrode array position for perimodiolar electrodes. The aims of this study were to verify the longterm reliability for the NRT-ratio in perimodiolar electrodes. In a retrospective controlled study in a Tertiary Referral Center the electrophysiological data sets of 123 patients with implanted Nucleus Contour Advance electrodes were enclosed. Intraoperative and up to 1 year follow-up Auto-NRTs were evaluated. A NRT-ratio was calculated by dividing the average Auto-NRT data from electrode 16 to 18 with the average from electrode 5 to 7. Using a flat panel tomography system, the position of the electrode array was certified radiological. 31 patients with perimodiolar electrodes with 1 year follow-up data were included in the study. Eleven patients showed regular follow-up NRT-ratio with a correlated and radiologically confirmed electrode position. 20 patients showed mismatches between the NRT-ratio and the radiological position. These patients were highly variable in terms of duration of deafness and neural spectrum disorders. The NRT-ratio can be used to determine the intracochlear position of the electrode array for perimodiolar electrodes. Intraoperatively the NRT-ratio predicts the array position within the cochlea highly reliable for perimodiolar electrodes. We showed that after 6 months and a year, the NRT-ratio remains unchanged in most of the cases and shows a good correlation to the radiological determined position of the array. Nevertheless, the condition of the neural structures is highly important for reproducible responses. Limited validity is given in patients with degenerative and structural neural disorders.

Indexed as

Cochlear ImplantsElectrodes, ImplantedTelemetryAdultCochleaCochlear ImplantationEar, InnerElectrophysiological PhenomenaFemaleFollow-Up StudiesHearing Loss, SensorineuralHearing TestsHumansIntraoperative PeriodMaleReproducibility of ResultsCochlear implantNRTQuality controlRadiology